BS 5467 Power cable

Wires & Cables Product Construction Technical Data Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Thickness of Outer Sheath Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL - XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1 sec Direct in Ground In Duct In Air Sq.mm Nos mm mm mm Kg/Km Ω/KM Cu Cu Cu Cu Cu Cu Cu ü Conductor : Annealed Plain copper conductor complying with BS 6360 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Inner sheath :PVC ü Jacket : PVC Complying with BS 6746 Siechem 2 Core Round APC Conductor EBXL - XLPE 120°C Insulated PVC Sheathed 600/1000 V (UA) Power cable as per BS 5467 Part Number Application Features ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :600/1000 V ü Test Voltage : 3.5 kV for 5 mins. ü Specification : BS 5467 741E1302 741E1602 741E1902 741E2302 742E2702 742E2802 742E3002 742E3202 1.5 2.5 4 6 10 16 25 35 1 1 1 1 7 7 7 7 0.6 0.7 0.7 0.7 0.7 0.7 0.9 0.9 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 11.6 12.8 13.9 15.0 16.9 19.0 22.4 24.7 168 213 264 326 442 604 871 1121 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.21 0.36 0.57 0.86 1.4 2.3 3.6 5.0 43 56 73 92 120 151 198 234 39 51 65 83 108 135 178 211 38 51 65 79 104 134 173 203 33 43 56 71 92 116 152 180 30 39 50 64 83 104 137 162 29 39 50 61 80 103 133 156 Siechem2CoreRoundAPCConductorEBXL -XLPE120°C InsulatedPVCSheathed 600/1000 (UA)Powercable asperBS 5467 ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. 741E Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 26 CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=