BS 5467 Power cable

Wires & Cables Product Construction Technical Data Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Thickness of Outer Sheath Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground In Duct In Air Sq.mm Nos mm mm mm Kg/Km Ω/KM Cu Cu Cu Cu Cu Cu Cu Part Number ü Conductor : Annealed Plain Copper conductor complying with BS 6360 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Jacket : PVC Complying with BS 6746 Siechem Single Core APC Conductor EBXL - XLPE 120°C Insulated PVC Sheathed 600/1000 V (UA) Power cable as per BS 5467 Application Features ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :600/1000 V ü Test Voltage : 3.5 kV for 5 mins. ü Specification : BS 5467 73934XX 73937XX 73938XX 73941XX 73942XX 73944XX 73946XX 73948XX 73949XX 73950XX 73951XX 73995XX 73953XX 50 70 95 120 150 185 240 300 400 500 630 800 1000 7 19 19 19 19 37 37 37 61 61 61 127 127 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 2.2 2.4 2.6 2.8 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9 2.0 2.2 2.3 2.4 14.2 16.2 18.3 20.2 22.4 24.7 27.7 30.6 34.2 38.0 42.9 47.8 53.0 565 761 1004 1243 1544 1884 2410 2989 3929 4892 6142 7732 9595 242 290 343 389 437 476 539 585 624 733 773 858 940 204 250 299 338 381 428 498 560 637 715 859 1043 1143 259 320 386 437 501 582 663 741 858 923 1073 1155 1266 0.387 0.268 0.193 0.153 0.124 0.9991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221 0.0176 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 71.4 90.0 114.4 143 186 223 264 299 336 366 415 450 480 564 594 660 723 157 192 230 260 293 329 383 431 490 550 661 756 850 199 246 297 336 385 448 510 570 660 710 825 945 1063 Siechem Single CoreAPC Conductor EBXL - XLPE 120°C Insulated PVC Sheathed 600/1000 V (UA) Power cable as per BS 5467 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. 739 Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 25 Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 ü Cables are also available in dual coloured insulation ü * Other length as per Customer order. CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=