BS 5467 Power cable
Wires & Cables Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground In Duct In Air Sq.mm Nos mm mm Kg/Km Ω/KM Dimension of Arm strips Thickness of Outer Sheath mm mm Al Al Al Al Al Al Al ü Conductor : Aluminium conductor complying with BS 6360 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Armour : GI strips ü Jacket : PVC Complying with BS 6746 Part Number Product Construction Technical Data 16 25 35 50 70 95 120 150 185 240 300 400 7 7 7 7 19 19 19 19 37 37 37 61 0.7 0.9 0.9 1 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.4 1.4 1.4 1.56 1.56 1.56 1.72 1.88 2.04 2.2 2.36 2.52 19.9 23.3 25.6 29.3 33.4 36.9 40.8 45.5 50.6 56.4 61.9 70.6 719 932 1127 1450 1835 2242 2695 3263 3922 4823 5765 7370 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 95 122 147 173 213 255 290 324 367 424 477 543 73 111 133 156 192 229 261 291 330 381 429 489 91 125 152 185 223 287 334 380 438 519 593 689 73 94 113 133 164 196 223 249 282 326 367 418 56 85 102 120 148 176 201 224 254 293 330 376 70 96 117 142 179 221 257 292 337 399 456 530 1.5 2.4 3.3 4.7 6.6 9.0 11.3 14.2 17.5 22.6 28.3 37.7 761EF2804 761EF3004 761EF3204 761EF3404 761EF3704 761EF3804 761EF4104 761EF4204 761EF4404 761EF4604 761EF4804 761EF4904 ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :600/1000 V ü Test Voltage : 3.5 kV for 5 mins. ü Specification : BS 5467 Siechem 4 Core Aluminium Conductor EBXL - XLPE 120°C Insulated GI strips Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467 Application Features ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. Siechem4CoreAluminiumConductorEBXL -XLPE120°C InsulatedGIstripsArmouredPVCSheathed 600/1000VPower cable asperBS 5467 761EF Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 24 CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=