BS 5467 Power cable

Wires & Cables Product Construction Technical Data Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Thickness of Outer Sheath Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground In Duct In Air Sq.mm Nos mm mm mm Kg/Km Ω/KM Al Part Number Al Al Al Al Al Al 16 25 35 50 70 95 120 150 185 240 300 400 7 7 7 7 19 19 19 19 37 37 37 61 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 1.8 2.0 2.0 2.0 2.2 2.2 2.4 2.6 2.8 3.0 3.2 3.4 19.1 22.9 25.2 28.5 33.1 36.6 40.5 45.3 50.5 56.4 62.0 70.8 438 631 .784 1022 1377 1725 2140 2667 3264 4117 5014 6529 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 95 122 147 173 213 255 290 324 367 424 477 543 73 111 133 156 192 229 261 291 330 381 429 489 91 125 152 185 223 287 334 380 438 519 593 689 73 94 113 133 164 196 223 249 282 326 367 418 56 85 102 120 148 176 201 224 254 293 330 376 70 96 117 142 179 221 257 292 337 399 456 530 1.5 2.4 3.3 4.7 6.6 9.0 11.3 14.2 17.5 22.6 28.3 37.7 759E2804 759E3004 759E3204 759E3404 759E3704 759E3804 759E4104 759E4204 759E4404 759E4604 759E4804 759E4904 ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :600/1000 V ü Test Voltage : 3.5 kV for 5 mins. ü Specification : BS 5467 ü Conductor : Aluminium conductor complying with BS 6360 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Inner sheath : PVC ü Jacket : PVC Complying with BS 6746 Siechem 4 Core Aluminium Conductor EBXL - XLPE 120°C Insulated PVC Sheathed 600/1000 V (UA) Power cable as per BS 5467 Application Features ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. Siechem 4 CoreAluminium Conductor EBXL - XLPE 120°C Insulated PVC Sheathed 600/1000 V (UA) Power cable as per BS 5467 ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. 759E Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 16 CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=