Nuclear cables

Application Product Construction Technical Data Features Wires & Cables ü Traceable ü Flame retardant ü Radiation stability ü Long term mositure ü Long - term thermal endurance ü Stripping for ease of termination ü Radiation resistant up to 200 megarads All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 18 www.siechem.com Catalogue No Part Number Cable Diameter (Nom.) Insulation Thickness (Nom.) Cable Weight (approx.) mm mm kg/km Outer Sheath Thickness mm No.of Strands / Stand dia Cond. Size (AWG) No.of Cond . 3/C 4/C 3/C 4/C 3/C 4/C 3/C 4/C 3/C 4/C 3/C 4/C 3/C 4/C 3/C 4/C 3/C 4/C 3/C 4/C 3/C 4/C 3/C 4/C 3/C 4/C 8 8 6 6 4 4 2 2 1 1 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 250 250 350 350 500 500 750 750 7/1.234 7/1.234 7/1.554 7/1.554 7/1.961 7/1.961 7/2.474 7/2.474 19/1.687 19/1.687 19/1.892 19/1.892 19/2.126 19/2.126 19/2.388 19/2.388 19/2.681 9/2.683 7/2.088 37/2.088 37/2.471 37/2.471 37/2.951 37/2.951 61/2.817 61/2.817 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.65 1.65 1.65 1.65 1.65 1.65 2.03 2.03 1.52 1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.79 2.03 2.79 2.79 2.79 2.79 2.79 2.79 3.56 16.0 17.5 18.0 19.8 20.6 23.7 24.8 27.3 28.3 31.1 30.1 33.3 32.6 36.0 35.3 39.1 38.4 44.0 42.1 48.2 54.5 49.3 56.3 62.4 67.8 76.8 470 582 686 853 1012 1267 1470 1854 1848 2485 2152 2749 2603 3343 3219 4134 3926 5227 4753 6103 6429 8312 8785 11379 13142 17059 o Siechem Annealed Tinned Copper Conductor, XLPE 90 C Insulated, ATC Drain Wire and CSPE Sheathed 600V rated cable ü Rated voltage : 600 V o ü Temperature rating :90 C ü Specification : (1) Class IE Qualified in accordance with IEEE 323-1974 and IEEE 383-1974 (2) ICEA S-95-658 (formerly ICEA S-66- 524 & S-19-81) (3) ANSI N45.2 ü Flame test : IEEE 383 (70,000 BTU/hr) as modified by NRC IEEE 383 (70,000 BTU/hr) IEEE 1202 (70, 000) BTU/hr) ICEA T-29-520 (210,000 BTU/hr) UL VW-1 ü Power cable is a 600 V multi- conductor, thermoset, Class IE rated Construction specifically designed for application in nuclear generating stations and where flame retardancy is critical. ü For use in class IE power distribution and control circuits for power lighting, control and signal circuits. ü Can be installed in trays, conduit, ducts or in direct burial applications. ü Conductor ü Insulation ü Drain wire ü Outer Sheath : : : : Annealed Tinned Copper Conductor as per ASTM B33 Cross-Linked polyethylene o (EBXL-XLPE 90 C) ATC Drain wire Heavy duty chorosulphonated polyethylene (CSPE) o SiechemAnnealedTinnedCopperConductor,EBXL -XLPE 90 C Insulated,ATCScreened andCSPESheathed 96276XX 96276XX 96275XX 96275XX 96274XX 96274XX 96273XX 96273XX 96272XX 96272XX 96290XX 96290XX 96291XX 96291XX 96292XX 96292XX 96294XX 96294XX 96241XX 96241XX 96244XX 96244XX 96246XX 96246XX 96249XX 96249XX 962 Drain Wire Size mm 10 10 8 8 8 8 6 6 6 6 6 6 6 6 4 4 4 4 4 4 3 3 2 2 1 1 AS 14001 ISO 45001 ISO 9001 IATF 16949 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=