Nuclear cables

o SiechemAnnealedTinnedCopperConductor,EBXL -XLPE90C Insulated&CSPESheathed600V ratedCableasPerULTypeTC Part Number Cable Diameter (Nom.) Insulation Thickness (Nom.) Cable Weight (approx.) No. of Strand/ Stand dia Application Product Construction Technical Data Wires & Cables Cond. Size (AWG) mm mm kg/km Outer Sheath Thickness mm No.of Cond . 2/C flat 2/C flat 2/C flat 2/C 3/C 4/C 5/C 7/C 9/C 12/C 19/C 25/C 30/C 37/C 2/C 3/C 4/C 5/C 7/C 9/C 12/C 19/C 25/C 30/C 37/C 2/C 3/C 4/C 5/C 7/C 9/C 12/C 19/C 14 12 10 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 10 7/0.615 7/0.775 7/0.978 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.775 7/0.775 7/0.775 7/0.775 7/0.775 7/0.775 7/0.775 7/0.775 7/0.775 7/0.775 7/0.775 7/0.978 7/0.978 7/0.978 7/0.978 7/0.978 7/0.978 7/0.978 7/0.978 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03 2.03 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 5.66 x 9.04 6.15 x 10.01 6.73 x 11.18 9.12 9.63 10.5 11.5 12.5 15.3 17.2 19.9 24.2 25.7 27.7 10.1 10.7 11.7 12.8 14.7 17.1 19.2 23.4 27.1 28.9 31.2 11.3 11.9 13.1 15.1 16.5 19.2 22.6 26.4 116 141 196 121 138 173 201 283 390 479 752 938 1176 1310 158 183 256 305 411 536 679 1049 1302 1511 1820 208 253 374 460 557 778 979 1453 o Siechem Multicore Annealed Tinned Copper Conductor, XLPE 90 C Insulated & CSPE Sheathed 600 V rated Cable ü Rated voltage : 600 V o ü Temperature rating : 90 C ü Specification : Class IE Qualified in accordance with IEEE 323-1974 and IEEE 383-1974 ICEA S-73-532(formerly ICEA S-66-524 & S-19-81) ü Flame Test : IEEE 383 (70,000 BTU/hr) as modified by NRC IEEE 383 (70,000 BTU/hr) IEEE 1202 (70,000 BTU/hr) ICEA T-29-520 (210,000 BTU/hr ) UL VW -1 ü Control cable is a 600 V multi-conductor, thermoset, Class IE rated Construction specifically designed for application in nuclear generating stations and where flame retardancy is critical. ü For use in class IE power distribution and control circuits for power lighting, control and signal circuits. ü Can be installed in trays, conduit, ducts or in direct burial applications. ü Conductor ü Insulation ü Outer sheath : : : Annealed Tinned copper Conductor as per ASTM B33 Cross-Linked polyethylene o (EBXL-XLPE 90 C) Heavy-duty chlorosulphonated polyethlene (CSPE) ü Traceable ü Flame retardant ü Radiation stability ü Long term moisture ü Long term thermal endurance ü Stripping for ease of termination ü Radiation resistant up to 200 megarads Features 95979XX 95978XX 95977XX 96079XX 96079XX 96079XX 96079XX 96079XX 96079XX 96079XX 96079XX 96079XX 96079XX 96079XX 96078XX 96078XX 96078XX 96078XX 96078XX 96078XX 96078XX 96078XX 96078XX 96078XX 96078XX 96077XX 96077XX 96077XX 96077XX 96077XX 96077XX 96077XX 96077XX Catalogue No 959 www.siechem.com 17 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. o SiechemMulticoreAnnealedTinnedCopperConductor,XLPE 90 C Insulated 600V ratedCable AS 14001 ISO 45001 ISO 9001 IATF 16949 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=