Nuclear cables
Application Product Construction Technical Data Features Wires & Cables All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 15 www.siechem.com Catalogue No Part Number Cable Diameter (Nom.) Insulation Thickness (Nom.) Cable Weight (approx.) mm mm kg/km Outer Sheath Thickness mm No. of Strands /Strand dia Cond. Size (AWG) No.of Conductor 2/C 3/C 4/C 5/C 7/C 9/C 12/C 19/C 25/C 30/C 37/C 2/C 3/C 4/C 5/C 7/C 9/C 12/C 19/C 25/C 30/C 37/C 18 18 18 18 18 18 18 18 18 18 18 16 16 16 16 16 16 16 16 16 16 16 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.080 0.080 7.39 7.77 8.43 10.1 10.9 12.4 14.5 16.6 19.0 20.1 22.6 7.85 8.26 8.97 11.0 11.8 14.3 15.8 18.1 20.7 23.0 24.6 79 85 110 121 150 186 234 362 460 530 637 91 109 131 155 195 244 333 478 609 768 911 ü Rated voltage : 600 V o ü Temperature rating : 90 C ü Specification : (1)Class IE Qualified in accordance with IEEE 323-1974 and IEEE 383-1974 (2) ICEA S-82-552 (formerly ICEA S- 66-524 & S-19-81) ü Flame Test : IEEE 383 (70,000 BTU/hr) as modified by NRC IEEE 383 (70,000 BTU/hr) IEEE 1202 (70,000 BTU/hr) ICEA T-29-520 (210,000 BTU/hr) UL VW -1 ü Traceable ü Flame retardant ü Radiation stability ü Long term moisture ü Long term thermal endurance ü Stripping for ease of termination ü Radiation resistant up to 200 megarads ü Conductor ü Insulation ü Outer sheath ü Overall shield : : : : Annealed Tinned Copper Conductor as per ASTM B33 Cross-Linked polyethylene o (EBXL-XLPE 90 C) Heavy duty chlorosulphonated polyethylene (CSPE) Aluminium/polyester tape in contact with a stranded tinned coppar drain wire o Siechem Annealed Tinned Copper Conductor, XLPE 90 C Insulated overall shielded with aluminium & ATC drain wire & CSPE sheathed 600 V Rated cable ü Instrumentation Cable is a 600 V overall shielded multi-conductor, thermoset, Class IE rated construction specifically designed for application in nuclear generating stations and where flame retardancy is critical. ü Designed for use on circuits where overall shielding is required to protect from external electrostatic interference, but not shielding between conductors. ü Can be installed in trays, conduit, ducts or in direct burial applications. o SiechemAnnealedTinnedCopperConductor, XLPE 90C Insulated overall shieldedwith aluminium&ATCdrainwire&CSPE sheathed 600VRated cable 95681XX 95681XX 95681XX 95681XX 95681XX 95681XX 95681XX 95681XX 95681XX 95681XX 95681XX 95680XX 95680XX 95680XX 95680XX 95680XX 95680XX 95680XX 95680XX 95680XX 95680XX 95680XX 956 AS 14001 ISO 45001 ISO 9001 IATF 16949 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=