Nuclear cables
Wires & Cables Part Number Cable Diameter (Nom.) Insulation Thickness (Nom.) Cable Weight (approx.) No. of Strands/ Strand dia Application Product Construction Technical Data Features All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 14 www.siechem.com Catalogue No ü Conductor ü Insulation ü Outer Sheath : : : Annealed Tinned Copper Conductor as per ASTM B33 Cross-Linked Polyethylene o (EBXL-XLPE 90 C) Heavy-duty chlorosulphonated polyethylene (CSPE) Size (AWG) mm mm kg/km Outer Sheath Thickness mm No.of Cond . 2/C flat 2/C flat 2/C 3/C 4/C 5/C 7/C 9/C 12/C 19/C 25/C 30/C 37/C 2/C 3/C 4/C 5/C 7/C 9/C 12/C 19/C 25/C 30/C 37/C 18 16 18 18 18 18 18 18 18 18 18 18 18 16 16 16 16 16 16 16 16 16 16 16 7/0.386 7/0.488 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.386 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 7/0.488 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 0.64 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 1.52 1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03 5.08 x 7.77 5.33 x 8.13 7.75 8.00 8.64 9.40 10.16 11.68 13.08 16.0 18.54 19.43 21.05 8.13 8.51 9.27 10.03 10.92 12.7 15.0 17.27 20.07 22.35 24.0 68 80 76 85 106 118 146 182 229 359 458 522 632 83 103 127 147 190 238 329 473 604 762 915 o Siechem Annealed Tinned Copper Conductor, XLPE 90 C Insulated & CSPE sheathed 600 V Rated cable ü Instrumentation Cable is a 600 V, multi-conductor, thermoset, Class IE rated construction specifically designed for application in nuclear generating stations and where flame retardancy is critical. ü For use in Class IE monitoring data recording and transmitting information on low energy circuits where shielding from external electrostatic interference is not required ü Can be installed in trays, conduit, ducts or in direct burial applications. ü Rated voltage : 600V o ü Temperature rating : 90 C ü Specification : (1) Class IE Qualified in accordance with IEEE 323-1974 and IEEE 383-1974 (2) ICEA S-82-552 (formerly ICEA S-66-524 & S-19-81) ü FlameTest : IEEE 383 (70,000 BTU/hr) as modified by NRC IEEE 383 (70,000 BTU/hr) IEEE 1202 (70,00 BTU/hr) ICEA T-29-520 (210,000 BTU/hr) UL VW-1 ü Traceable ü Flame retardant ü Radiation stability ü Long-term moisture ü Long term thermal endurance ü Stripping for ease of termination ü Radiation resistant up to 200 megarads o SiechemAnnealed Tinned Copper Conductor, XLPE 90 C Insulated & CSPE sheathed 600 V Rated cable 95481XX 95480XX 95581XX 95581XX 95581XX 95581XX 95581XX 95581XX 95581XX 95581XX 95581XX 95581XX 95581XX 95580XX 95580XX 95580XX 95580XX 95580XX 95580XX 95580XX 95580XX 95580XX 95580XX 95580XX 954-955 AS 14001 ISO 45001 ISO 9001 IATF 16949 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=