Nuclear cables
Part Number Cable Diameter (Nom.) Insulation Thickness (Nom.) Cable Weight (approx.) No. of Strands/ Strand dia Application Product Construction Technical Data Features Wires & Cables All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 13 www.siechem.com Catalogue No 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000 7/0.615 7/0.775 7/0.978 7/1.234 7/1.554 7/1.961 7/2.474 19/1.687 19/1.892 19/2.126 19/2.388 19/2.68 37/2.088 37/2.471 37/2.951 61/2.817 61/3.251 Cond. Size (AWG) mm mm kg/km 0.76 0.76 0.76 1.14 1.14 1.14 1.14 1.40 1.40 1.40 1.40 1.40 1.65 1.65 1.65 2.03 2.03 Outer Sheath Thickness mm 0.38 0.38 0.38 0.38 0.76 0.76 0.76 1.14 1.14 1.14 1.14 1.14 1.65 1.65 1.65 1.65 1.65 4.19 4.67 5.26 6.81 8.53 9.73 11.2 13.5 14.5 15.6 16.9 18.3 21.1 23.7 27.0 32.3 36.1 34 48 69 112 177 260 388 506 620 760 935 1154 1410 1911 2653 3915 5131 o Siechem Annealed Tinned Copper Conductor, XLPE 90 C Insulated & CSPE Sheathed 600 V rated Cable ü Power Cable is a 600 V, insulated dual wall, single conductor class IE rated wire construction specifically designed for application in nuclear generating station and where additional jacketing protection is required. ü For use in Class IE low voltage Power and lighting functions where optimum performance is required ü May be installed in trays, conduit, ducts, or direct buried. ü Rated voltage : 600 V o ü Temperature rating : 90 C ü Specification : (1) Class IE Qualified in accordance with IEEE 323-1974 and IEEE 383-1974 (2) ICEA S-95-658 (formerly ICEA S-66- 524 & S-19-81) ü FlameTest : IEEE 383 (70,000 BTU/hr) ICEA T-29-520 (210,000 BTU/hr) UL VW-1 ü Traceable ü Radiation stability ü Long term moisture ü Long term thermal endurance ü Stripping for ease of termination ü Radiation resistant up to 200 megarads ü Conductor ü Insulation ü Outer sheath : : : Annealed Tinned Copper Conductor as per ASTM B33 Cross Linked Polyethylene o (EBXL-XLPE 90 C Heavy duty chlorosulporated polyethylene (CSPE) o SiechemAnnealedTinnedCopperConductor,XLPE 90 C Insulated&CSPESheathed 600V ratedCable 95379XX 95378XX 95377XX 95376XX 95375XX 95374XX 95373XX 95372XX 95390XX 95391XX 95392XX 95394XX 95341XX 95344XX 95346XX 95349XX 95350XX 953 AS 14001 ISO 45001 ISO 9001 IATF 16949 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=