Marine cable
Wires & Cables www.siechem.com Part Number Product Construction Technical Data Temperature Range Operating Voltage Specification 0 0 : - 40 C to +120 C : 60V : IEC 60092-375 Conductor Insulation Inner Sheath Separator Screen Outer Sheath : Electrolytic Annealed Copper Conductor IEC 60227 Class 2 : EPR : LFH : Separator tape : Annealed Tinned Copper Braided : LFH No. of Cores 2 and mm Per Conductor Siechem Multipair Marine Cable Siechem Multi Pair APC Conductor, EPR Insulated, ATC Screened LFH Sheathed Marine Cable for Instrumentation Circuits as per IEC 60092-375 Catalogue No 906E Outer Diameter in (mm) (approx.) Total Weight (Kg/Km) (approx.) No. of Strands / Strand Diameter (mm) (Nom.) Insulation Thickness (mm) (Nom.) Inner Sheath Thickness (mm) (Nom.) Outersheath Thickness (mm) (Nom.) 210 1P x 0.5 2P x 0.5 4P x 0.5 7P x 0.5 10P x 0.5 14P x 0.5 19P x 0.5 24P x 0.5 30P x 0.5 37P x 0.5 48P x 0.5 1T x 0.5 1P x 0.75 2P x 0.75 4P x 0.75 7P x 0.75 10P x 0.75 14P x 0.75 19P x 0.75 24P x 0.75 30P x 0.75 37P x 0.75 48P x 0.75 1T x 0.75 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.2 1.3 1.4 0.8 0.8 0.8 0.9 0.9 1.0 1.1 1.1 1.3 1.3 1.3 1.4 1.8 Diameter of Braided Screen (mm) (Nom.) 0.20 0.20 0.20 0.20 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.20 0.20 0.20 0.20 0.20 0.25 0.25 0.25 0.25 0.25 0.30 0.30 0.20 1.1 1.1 1.2 1.2 1.3 1.3 1.4 1.4 1.5 1.5 1.6 1.1 1.1 1.1 1.2 1.3 1.3 1.4 1.5 1.5 1.6 1.7 1.8 1.1 8.0 11.0 13.0 15.0 19.0 20.5 23.0 27.0 29.0 31.0 35.5 12.0 11.0 14.5 17.0 20.0 25.0. 27.0 30.1 34.5 37.0 40.0 45.5 11.5 125 190 265 360 510 620 765 940 1105 1290 1675 195 170 255 360 500 705 880 1100 1340 1580 1900 2395 195 906E0601P 906E0602P 906E0604P 906E0607P 906E0610P 906E0614P 906E0619P 906E0624P 906E0630P 906E0637P 906E0648P 906E0601T 906E0801P 906E0802P 906E0804P 906E0807P 906E0810P 906E0814P 906E0819P 906E0824P 906E0830P 906E0837P 906E0848P 906E0801T Application Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Features Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact Halogen free Super-flexible at 4/0 AWG and larger Meets IEEE standards for 600V / IEC standards for 0.6/1kV AS 9100 ISO 45001 ISO 9001 ISO 14001 IRS DGQA
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=