Marine cable
Wires & Cables 2 TABLE I (Z) : Three Core Cables - Colletively Screened 2.5mm Siechem Multicore - Unscreened Marine Cable Application Product Construction Technical Data Power, Lighting, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Features Limited Fire Hazard Halogen free Temperature Range Rated Voltage (U /U) o Test Voltage Bending Radius Flexing Fixed Specification 0 0 : - 30 C to +85 C : 600 V : 1.5 kV : 10 x Cable Diameter : 4 x Cable Diameter : Def Stan 61-12 (Part 25/2) Conductor Insulation Collective Sceen Laying up Outer Sheath : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : ATC : Limited Fire Hazard complying with LFH Def stand 61-12 Part 31 Material . 891-9424 891-9425 3C x 2.5 3C x 2.5 8.0 8.0 9.6 9.6 1.0 1.0 6.1 6.1 0.12 0.12 Part Number Number of Cores 2 and mm Per Conductor Outer Diameter in (mm) Total Weight Kg/Km approx. Radial Thickness of Sheath (mm) Max. Conductor 0 Resistance at 20 C ( Ω /km) Min Max 146 146 5.6 5.6 7.6 7.6 * Note : *Denotes type 2 cable as per Def Stand 61-12 part 18 Issues 5 and 1 Nominal Diameter Over Cores (mm) Diameter of Collective screen wire (mm) Nominal Diameter of Over collective screen (mm) www.siechem.com 201 Catalogue No DEF 61-12 P25/2 T I (Z) AS 9100 ISO 45001 ISO 9001 ISO 14001 IRS DGQA