Marine cable

Wires & Cables 2 TABLE I (S) : Two Core Cables - Unscreened 2.5mm Siechem Multicore - Unscreened Marine Cable Application Product Construction Technical Data Power, Lighting, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Features Limited Fire Hazard Halogen free Temperature Range Rated Voltage (U /U) o Test Voltage Bending Radius Flexing Fixed Specification 0 0 : - 30 C to +85 C : 600 V : 1.5 kV : 10 x Cable Diameter : 4 x Cable Diameter : Def Stan 61-12 (Part 25/2) Conductor Insulation Laying up Outer Sheath : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Limited Fire Hazard complying with LFH Def stand 61-12 Part 31 Material . 891-9410 891-9411 2C x 1.0 2C x1.0 6.30 6.30 5.10 5.10 1.0 1.0 Part Number 2 Number of Cores and mm Per Conductor Outer Diameter in (mm) Total Weight Kg/Km approx. Nominal Diameter Over Cores (mm) Radial Thickness of Sheath (mm) Max. Conductor 0 Resistance at 20 C ( Ω /km) Min Max 47 47 3.30 3.30 21.1 21.1 * Note : *Denotes type 2 cable as per Def Stand 61-12 part 18 Issues 5 and 1 www.siechem.com 194 Catalogue No DEF 61-12 P25/2 T I (S) AS 9100 ISO 45001 ISO 9001 ISO 14001 IRS DGQA

RkJQdWJsaXNoZXIy NDgyMjA=