Irrigation Communication Cable

18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 B825S8102 B825S8103 B825S8104 B825S8105 B825S8106 B825S8107 B825S8108 B825S8109 B825S8110 B825S8111 B825S8112 B825S8113 B825S8114 B825S8115 B825S8116 B825S8117 B825S8118 B825S8119 B825S8120 B825S8121 B825S8122 B825S8123 B825S8124 B825S8125 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Conductor Diameter (Nom) Nominal Cross Sectional Area No. of Cores No. of Strands Conductor Construction Cable Part number mm Overall Diameter (Nom) Weight Approx Colour Code 5.23 5.54 6.02 6.55 7.10 7.10 7.96 8.60 9.00 9.00 9.30 9.75 9.75 10.30 10.30 10.80 10.80 10.80 11.50 11.50 12.10 12.10 12.70 12.70 mm kg/km AWG Nos Nos 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.02 310 455 600 750 895 1035 1185 1330 1480 1625 1770 1920 2060 2210 2355 2500 2650 2795 2945 3090 3240 3385 3530 3675 R,W R,W,L R,W,L,G R,W,L,G,Br R,W,L,G,Br,B, R,W,L,G,Br,B,Y R,W,L,G,Br,B,Y,O R,W,L,G,Br,B,Y,O,Pr R,W,L,G,Br,B,Y,O,Pr,Gr R,W,L,G,Br,B,Y,O,Pr,Gr,T R,W,L,G,Br,B,Y,O,Pr,Gr,T,P R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W,R/L R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W,R/L,R/G, R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W,R/L,R/G,R/Br R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W,R/L,R/G,R/Br,R/B R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W,R/L,R/G,R/Br,R/B,R/Y R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W,R/L,R/G,R/Br,R/B,R/Y,R/O R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W,R/L,R/G,R/Br,R/B,R/Y,R/O,R/Pr R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W,R/L,R/G,R/Br,R/B,R/Y,R/O,R/Pr,R/Gr, R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W,R/L,R/G,R/Br,R/B,R/Y,R/O,R/Pr,R/Gr,R/T, R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W,R/L,R/G,R/Br,R/B,R/Y,R/O,R/Pr,R/Gr,R/T, R/P, R,W,L,G,Br,B,Y,O,Pr,Gr,T,P,LTB,R/W,R/L,R/G,R/Br,R/B,R/Y,R/O,R/Gr,R/Pr,R/T, R/P, R/LB ü Conductor : Annealed Bare solid Copper Conductor according to ASTM Spec.B3 ü Insulation : PVC (Polyvinyl Chloride) Nylon ripcord ü Jacket : HDPE (Black) Application Product Construction Technical Data Features Wires & Cables www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Siechem Under Ground Low Energy Irrigation Circuit Cable ü Voltage Rating :30 V ü Temperature Range : -30ºC to +80ºC ü Standards : As per customer specifications or Generally as per UL 493 and 83 ü DC Conductor Resistance at 20°C : 21 4 Ω /km Catalogue No. BS825S 2D View ü Used to transmit and receive signals between Irrigation satellites, Central Computers, weather stations and sensors. ü Its mainly used in Irrigation satellites & Smart Hub Systems. ü Used in Underground Low Energy Systems. ü Used in Sprinklers Systems. ü Controller outputs to the solenoid values ü Outdoor Accent Lighting, Landscape Lighting, & Security Lighting. ü Direct Burial. ü Sunlight and Moisture resistant. ü Reduces Radio frequency interference. ü And also minimizing the electrical and magnetic interference. ü UV and Sunlight Resistant Siechem Under Ground Low Energy Irrigation Circuit Cable Red-R Yellow-Y Blue-L Black-B Green-G White-W Grey-Gr Brown-Br Orange-O Red/White-R/W Red/Blue-R/L Red/Green-R/G Red/Brown-R/Br Red/Black-R/B Red/Yellow-R/Y Red/Orange-R/O Red/Purple-R/Pr Red/Grey-R/Gr Red/Tan-R/T Red/Pink-R/P Tan-T Light Blue-LTB Red/Light Blue-R/LTB Purple-Pr Pink-P 19 AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949

RkJQdWJsaXNoZXIy NDgyMjA=