Irrigation Communication Cable
Max. Conductor Resistance at 20°C Current Rating ü Conductor : Soft-Annealed Plain Stranded Copper Conductor ü Insulation : PE (Polyethylene) ü Insulation Colour : As per Customer Order ü Outer Sheath : PVC ü Sheath Colour :Red ü Multicore Application Product Construction Technical Data Features 3C x 0.5 5C x 0.5 7C x 0.5 9C x 0.5 13C x 0.5 2C x 1.0 3C x 1.0 5C x 1.0 7C x 1.0 9C x 1.0 13C x 1.0 2C x 1.5 3C x 1.5 5C x 1.5 7C x 1.5 9C x 1.5 13C x 1.5 2C x 2.5 3C x 2.5 5C x 2.5 7C x 2.5 9C x 2.5 13C x 2.5 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 Wires & Cables All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Diameter of Single Wire (Nom) Insulation Wall Thickness (Nom) Nominal Cross Sectional No. of Strand Conductor Construction Part number mm Overall Diameter (Nom) Approx Weight of Cable 4.9 ± 0.5 5.8 ± 0.5 6.3 ± 0.5 7.6 ± 0.5 8.7 ± 0.5 6.0 ± 0.5 6.3 ± 0.5 7.6 ± 0.5 8.2 ± 0.5 10.2 ± 0.5 11.6 ± 0.5 6.4 ± 0.5 6.8 ± 0.5 8.1 ± 0.5 9.0 ± 0.5 11.0 ± 0.5 12.5 ± 0.5 7.3 ± 0.5 7.8 ± 0.5 9.6 ± 0.5 10.5 ± 0.5 12.8 ± 0.5 14.8 ± 0.5 38.4 38.4 38.4 38.4 38.4 21.2 21.2 21.2 21.2 21.2 21.2 13.6 13.6 13.6 13.6 13.6 13.6 7.41 7.41 7.41 7.41 7.41 7.41 35 50 65 85 120 45 60 90 120 160 215 55 70 110 150 195 270 80 110 175 230 295 420 mm mm kg/km mm Sq.mm Nos Ω /km A 2D View Siechem Control Valve Wiring ü For use in automatic irrigation systems to connect solenoid valves to controller. ü Suitable for direct burial. ü Not suitable for connection to Mains Power Supply ü Used in Extra Low Energy Systems. ü Maximum Conductor : +90ºC Temperature ü Maximum Short Circuit : +250ºC Conductor Temperature ü Non-Hydroscopic fillers inserted in the valleys to ensure roundness. ü Standards : As per customer specifications or generally similar to AS 3808. ü Direct Burial. ü Sunlight and Moisture resistant. ü High Cut-through resistance. ü High Tensile Strength. ü High Abrasion resistance. Siechem Control Valve Wiring Siechem offers Electron Beam Cross Linked XLPE cables, short circuit resistant at 280ºC for 3 minutes with - 45ºC to + 125ºC continuously rated cables on demand. Outer Sheath Thickness (Nom) B5650603 B5650605 B5650607 B5650609 B5650613 B5651002 B5651003 B5651005 B5651007 B5651009 B5651013 B5651302 B5651303 B5651305 B5651307 B5651309 B5651313 B5651602 B5651603 B5651605 B5651607 B5651609 B5651613 Siechem Wires & Cables Meet EU RoHS Directive Catalogue No. B565 www.siechem.com 0.30 0.30 0.30 0.30 0.30 0.43 0.43 0.43 0.43 0.43 0.43 0.50 0.50 0.50 0.50 0.50 0.50 0.67 0.67 0.67 0.67 0.67 0.67 0.30 0.30 0.30 0.30 0.30 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.60 0.60 0.60 0.60 0.70 0.60 0.60 0.60 0.60 0.70 0.70 0.60 0.60 0.60 0.70 0.70 0.70 0.60 0.60 0.70 0.70 0.70 0.80 4 4 4 4 4 10 10 10 10 10 10 16 16 16 16 16 16 23 23 23 23 23 23 14 AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=