Irrigation Communication Cable
Max. Conductor Resistance at 20°C Current Rating in Air at 30ºC Outer Sheath Thickness (Nom) ü Conductor : Soft-Annealed Solid Bare Copper Conductor ü Insulation : PE (Polyethylene) ü Insulation Colour : Black & White ü Inner Sheath: Extruded Non-hydroscopic Polyvinyl Chloride - White ü Outer Sheath : (HDPE) High Density Polyethylene ü Sheath Colour :Red ü Multicore Application Product Construction Technical Data Features 2C x 1.5 2C x 2.5 1 1 1.38 1.77 2.80 3.16 0.5 0.5 0.7 0.7 Wires & Cables www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Diameter of Single Wire (Nom) Insulation Wall Thickness (Nom) Insulation Diameter (Nom) Inner Sheath Thickness (Nom) Nominal Cross Sectional No. of Strand Conductor Construction Part number mm mm mm Overall Diameter (Nom) Approx Weight of Cable 10.7 ± 1.1 11.5 ± 1.2 12.1 7.41 130 165 1.8 1.8 mm mm kg/km mm Sq.mm No Ω /km A Catalogue No. A801 2D View Siechem Irrigation Control Cables ü Used to transmit and receive signals between Irrigation satellites, Central Computers, weather stations and sensors. ü Its mainly used in Irrigation satellites & Smart Hub Systems. ü Used in Underground Low Energy Systems. ü Used in Sprinklers Systems. ü Maximum Conductor : +90ºC Temperature ü Maximum Short Circuit : +250ºC Conductor Temperature ü Non-Hydroscopic fillers inserted in the valleys to ensure roundness. ü Current Rating Details : ü Maximum Current in Buried at 15ºC (Amps) : I) 1.5 Sq.mm : 42 Amps ii) 2.5 Sq.mm : 48 Amps ü Maximum Current in Air at 30ºC (Amps) : i) 1.5 Sq.mm : 32 Amps ii) 2.5 Sq.mm : 36 Amps ü Standards : As per customer specifications or generally similar to UL 1493 & UL 1581. ü Direct Burial. ü Sunlight and Moisture resistant. ü High Cut-through resistance. ü High Tensile Strength. ü High Abrasion resistance. 32 36 A8011302 A8011602 Siechem Irrigation Control Cables Siechem offers Electron Beam Cross Linked XLPE cables, short circuit resistant at 280ºC for 3 minutes with - 45ºC to + 125ºC continuously rated cables on demand. 13 AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=