Indian Railway Cables new.cdr
Note : XX* : Please add last two digits in the part number as per the colour code given here under replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 Application Product Construction Technical Data Features Conductor Dia. Nominal (mm) ü Conductor : Annealed Tinned Flexible Copper Conductor ü Insulation : Electron Beam Cross Linked Polyolefin. ü Outersheath : Electron Beam Cross Linked Polyolefin. ü Temperature range : Operating temp. :-40°C to +120°C ü Rated voltage : Above 750V upto 1.8/3kV ü Short circuit temperature : +280°C. ü Test voltage : 8kV for 15 mins. ü Min. bending radius : 3 x D for cable dia <10mm 5 x D for cable dia >10mm ü Insulation resistance constant ( at room temp) : K ≥ 12000 M Ω .Km ü Specification : ELRS / SPEC / ELC / 0019 Rev 4. ü Thin walled flexible EBXL cables for tap changer of electric locomotives, AC/DC EMU, BG, AC EMU & MEMU coaching stock. ü Limited fire hazard type ü Minimum flame spread ü Low smoke emission ü Limited toxic fume emission ü Resistant to mineral oil, diesel, etc. Single Core above 750V and Upto 1.8/3kV Thin Walled Flexible EBXL Cables for Electric Locomotives Nominal Cross Sectional Area 2 of Core (mm ) Minimum wall Thickness of Insulation (mm) Wires & Cables Catalogue No. A532 Part Number Siechem 1.8/3.0kV 300 Sq.mm EBXL - HR 120ºC Cable 19 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing an Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Overall Cable Dia (D) (mm) Max. Resistance of Conductor at 20 deg. C (ohm/km) Minimum wall Thickness of Sheath (mm) No. of Wires x Wire Dia. (max) (Nos. x mm) Approx. Cable Weight (Kg/Km) A5321309XX A5321609XX A5321909XX A5322309XX A5322709XX A5322809XX A5323009XX A5323209XX A5323409XX A5323709XX A5323809XX A5324109XX A5324209XX A5324409XX A5324609XX A5324809XX 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 30 x 0.26 50 x 0.26 56 X 0.31 84 x 0.31 80 x 0.41 126 x 041 196 x 0.41 266 x 0.41 384 x 0.41 348 x 0.51 468 x 0.51 589 x 0.51 741 x 0.51 888 x 0.51 1184 x 0.51 1480 x 0.51 1.6 2.1 2.7 3.3 4.2 5.5 6.8 7.8 9.5 11.5 12.9 14.8 16.3 18.5 21.0 23.5 0.30 0.30 0.35 0.35 0.40 0.50 0.60 0.65 0.70 0.75 0.85 0.95 1.00 1.05 1.10 1.15 0.40 0.40 0.45 0.45 0.50 0.70 0.80 0.85 0.90 0.95 1.05 1.15 1.20 1.25 1.30 1.35 3.20 ± 0.10 3.70 ± 0.15 4.50 ± 0.15 5.10 ± 0.15 6.30 ± 0.20 8.30 ± 0.20 10.2 ± 0.30 11.7 ± 0.30 13.6 ± 0.30 15.6 ± 0.30 17.3 ± 0.30 19.6 ± 0.30 21.9 ± 0.30 23.8 ± 0.30 26.9 ± 0.30 29.7 ± 0.30 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654 32.6 45.2 61.0 78.5 111 153 203 255 322 402 489 578 670 705 753 878 20 30 50 70 120 190 280 390 550 740 960 1200 1550 1865 2390 2955 Current Rating in air 30°C AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=