Indian Railway Cables new.cdr

Application Product Construction Technical Data Features ü Conductor : Annealed Tinned Flexible Copper Conductor ü Insulation : EBXL - EPDM 120ºC (Dual layer) ü Outersheath : Electron Beam Cross Linked Polyolefin. ü Temperature range : Operating temp. :-40ºC to +120ºC. High insualtion resistance at elevated temp. ü Rated voltage : Above 750V upto 1.8/3kV ü Short circuit temperature : +280ºC. ü Test voltage : 6kV for 15 mins. ü Min. bending radius : 3 x D for cable dia <10mm 5 x D for cable dia >10mm ü Insulation resistance constant ( at room temp) : K ≥ 12000 M Ω .Km ü Specification : ELRS / SPEC / ELC / 0019 Rev 2. ü Thin walled flexible EBXL cables for tap changer of electric locomotives, AC/DC EMU, BG, AC EMU & MEMU coaching stock. ü Limited fire hazard type ü Minimum flame spread ü Low smoke emission ü Limited toxic fume emission ü Resistant to mineral oil, diesel, etc. Single Core above 750V and Upto 1.8/3kV Thin Walled Flexible EBXL Cables for Electric Locomotives Nominal Cross Sectional Area 2 of Core (mm ) Wires & Cables Catalogue No. 258 Part Number Siechem 1.8/3.0kV 300 Sq.mm EBXL - HR 120ºC Cable 11 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 25813XXYY 25816XXYY 25819XXYY 25823XXYY 25827XXYY 25828XXYY 25830XXYY 25832XXYY 25834XXYY 25837XXYY 25838XXYY 25841XXYY 25842XXYY 25844XXYY 25846XXYY 25848XXYY 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 3.20 ± 0.10 3.70 ± 0.15 4.50 ± 0.15 5.10 ± 0.15 6.30 ± 0.20 8.30 ± 0.20 10.2 ± 0.30 11.7 ± 0.30 13.6 ± 0.30 15.6 ± 0.30 17.3 ± 0.30 19.6 ± 0.30 21.9 ± 0.30 23.8 ± 0.30 26.9 ± 0.30 29.7 ± 0.30 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654 30 x 0.26 50 x 0.26 56 x 0.31 84 x 0.31 80 x 0.41 126 x 0.41 198 x 0.41 266 x 0.41 385 x 0.41 348 x 0.51 468 x 0.51 589 x 0.51 741 x 0.51 912 x 0.51 1184 x 0.51 1480 x 0.51 Overall Cable Dia (D) (mm) Max. Resistance of Conductor at 20 deg.C (ohm/km) No. of Wires x Wire Dia. (max) (Nos. x mm) Approx. Cable Weight (Kg/Km) 22.5 33.5 51.0 71.5 114.0 186.0 294.0 399.0 545.5 755.0 1003.0 1268.0 1565.0 1907.0 2449.0 3026.0 Note : XX* & YY* : Please add last two digits in the part number as per the colour code given here under replacing XX while ordering YY. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO

RkJQdWJsaXNoZXIy NDgyMjA=