Flexible cable

Application Product Construction Technical Data Features Wires & Cables ü Conductor : Annealed Copper Conductor, Class 5 Flexible Conductor EN 60228 ü Optional : Tinned Copper ü Insulation : Cross Linked Elastomeric Compound Type EI 6 As Per En 50363-1 ü Sheath : Cross Linked Elastomeric Compound Type EM 6 to EN 50363-2-1 Siechem H07BB-F 450 / 750 V Multicore Flexible Cables RoHS Siechem Annealed Plain Copper Conductor 450/750V Rubber Insulated and Sheathed Muilticore Heavy duty Cables ( H07BB-F ) Part Number Number of Cores Thickness of insulation Overall diameter Weight approx. 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 1 1.5 2.5 4 6 10 16 25 35 50 70 95 1 1.5 2.5 4 6 10 16 25 0.8 0.9 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.0 0.8 0.8 0.9 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 0.8 0.8 0.9 1.0 1.0 1.2 1.2 1.4 Thickness of Sheath 1.4 1.4 1.5 1.6 1.8 1.9 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.5 3.6 3.8 4.0 4.1 1.3 1.5 1.7 1.8 2.0 3.1 3.3 3.6 3.8 4.2 4.6 5.0 1.4 1.6 1.8 1.9 2.1 3.3 3.5 3.8 5.7 6.3 7.2 7.9 9.5 10.8 12.7 14.3 16.5 18.6 20.8 22.8 25.2 27.6 30.6 33.5 37.4 41.3 45.5 7.7 8.5 10.2 11.8 13.1 17.7 20.2 24.3 27.2 31.6 35.8 40.2 8.3 9.2 10.9 12.7 14.1 19.1 21.8 26.1 Minimum Maximum 7.1 7.9 9.0 9.8 11.9 13.4 15.8 17.9 20.6 23.3 26.0 28.6 31.4 34.4 38.3 41.9 46.8 52 57 10.0 11.0 13.1 15.1 16.8 22.6 25.7 30.7 34.3 39.8 45.1 51 10.7 11.9 14.0 16.2 18.0 24.2 27.6 33.0 2 mm mm mm mm mm mm mm Single layer Double layers Inner layers Outer layer - - - - - - - - - 1.0 1.1 1.2 1.3 1.4 1.4 1.4 1.5 1.6 1.6 - - - - - 1.2 1.3 1.4 1.5 1.7 1.8 2.0 - - - - - 1.3 1.4 1.5 - - - - - - - - - 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 - - - - - 1.9 2.0 2.2 2.3 2.5 2.8 3.0 - - - - - 2.0 2.1 2.3 ü Specification :BS EN 50525-2-21:2011 BS-6500 ü Operating Temperature :-25°C to 90°C ü Test voltage : 2.5 kV ü Conductor resistance : EN 60228 ü Rated Voltage : (u /u) 450/750 V o ü Fire resistant : EN 60332-1-2 Kg/Km 69 87 115 144 213 286 401 520 715 937 1221 1489 1827 2216 2787 3400 4397 5405 6619 119 147 204 285 364 644 849 1190 1499 2061 2674 3457 141 175 244 344 441 781 1042 1472 Size 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 Max conductor resistance 0 at 20 C Ω /km 13.3 7.98 4.95 3.30 1.91 1.21 0.780 0.554 0.386 0.272 0.206 0.161 0.129 0.106 0.0801 0.0641 0.0486 0.0384 0.0287 19.5 13.3 7.98 4.95 3.30 1.91 1.21 0.780 0.554 0.386 0.272 0.206 19.5 13.3 7.98 4.95 3.30 1.91 1.21 0.780 mm Max Conductor diameter 1.8 2.4 3.0 3.9 5.1 6.3 7.8 9.2 11.0 13.1 15.1 17.0 19.0 21.0 24.0 27.0 31.0 35.0 39.0 1.5 1.8 2.4 3.0 3.9 5.1 6.3 7.8 9.2 11.0 13.1 15.1 1.5 1.8 2.4 3.0 3.9 5.1 6.3 7.8 Nos. A02013XXYY A02016XXYY A02019XXYY A02023XXYY A02027XXYY A02028XXYY A02030XXYY A02032XXYY A02034XXYY A02037XXYY A02038XXYY A02041XXYY A02042XXYY A02044XXYY A02046XXYY A02048XXYY A02049XXYY A02050XXYY A02051XXYY A0211002 A0211302 A0211602 A0211902 A0212302 A0212702 A0212802 A0213002 A0213202 A0213402 A0213702 A0213802 A0211003 A0211303 A0211603 A0211903 A0212303 A0212703 A0212803 A0213003 2D View ü Use for medium mechanical stress in dry, damp and wet areas ü Handling equipment,In open air for agriculture plants ü Installation on plaster, in temporary buildings and residential barracks ü Mobile power supplies, Worksites, stage and audio visual equipment ü Port areas and dams, use in drainage and water treatment ü Severe industrial environments like boilers, heating plates for transportable motors or machines at site. ü Flame Retardant according to IEC/EN 60332-1-2 ü High flexibility, Weather resistance, oil & grease resistant ü Capacity to withstand mechanical and thermal stresses ü In dry, damp and wet areas AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=