Flexible cable
Wires & Cables Application Product Construction Technical Data Features Siechem SFLEX CLASSIC 110CY 0.5kV Flexible Cables RoHS ü To avoid electrical interference in motors run by frequency converters. ü Transport and Data processing systems. ü Air conditioning systems. ü Highly resistant to oils and chemicals. ü Excellent insulation performance and flame retardant. ü Copper braiding reduces electromagnetic interference between cable and environment . ü Transfer Impedance has low value. ü Conductor : Finely Stranded Bare Copper Wires. ü Insulation : PVC Compound ü Inner Sheath : PVC Material and with Grey Color. ü Braiding : Tinned Copper Wire. ü Outer Sheath : Transparent PVC Material. ü Temperature Range : 0 0 Flexible applications : - 5 C to +70 C 0 0 Fixed Installation : - 40 C to +80 C ü Voltage for Testing : 4 kV ü Protective Conductor(PC) : G-With green/yellow PC X-Without PC ü Bending Radius(Minimum) : Flexing : 20x Cable Diameter Static : 6 x Cable Diameter ü Rated Voltage : (U /U) 300/500 V 0 ü Specific Insulation Resistance : >20 G Ohm x cm. ü As per VDE 7030 Part Number 2 Number of Cores and mm Per Conductor Outer Diameter in mm approx. Copper Index Kg/Km Weight Kg/Km approx. 2Cx0.5 8.11 41.04 99.62 3G0.5 8.45 45.45 108.60 3Cx0.5 8.45 45.45 108.60 4G0.5 9.00 54.98 126.80 4Cx0.5 9.00 54.98 126.80 5G0.5 9.60 61.39 143.46 5Cx0.5 9.60 61.39 143.46 7G0.5 10.24 80.52 173.47 7Cx0.5 10.24 80.52 173.47 12G0.5 12.46 138.52 258.32 12Cx0.5 12.46 138.52 258.32 18G0.5 14.25 170.01 326.36 25G0.5 16.38 230.01 429.28 30G0.5 17.25 279.37 505.32 40G0.5 19.21 343.02 623.65 2Cx0.75 8.93 46.36 117.92 3G0.75 9.34 57.00 134.49 3Cx0.75 9.34 57.00 134.49 4G0.75 10.00 66.23 155.20 4Cx0.75 10.00 66.23 155.20 5G0.75 10.71 77.44 180.05 5Cx0.75 10.71 77.44 180.05 7G0.75 11.47 96.04 213.09 7Cx0.75 11.47 96.04 213.09 12G0.75 14.17 168.95 319.83 12Cx0.75 14.17 169.04 319.92 18G0.75 16.30 243.07 442.94 18Cx0.75 16.30 243.07 442.94 25G0.75 18.84 293.04 550.38 34G0.75 21.13 341.32 667.03 40G0.75 21.97 388.54 755.31 41G0.75 23.08 488.05 867.15 2Cx1 9.87 56.21 144.19 3G1 10.14 67.72 158.47 3Cx1 10.14 67.72 158.47 4G1 11.29 80.76 196.34 4Cx1 11.29 80.76 196.34 5G1 12.11 94.10 227.62 7G1 12.48 116.83 269.31 12G1 14.67 188.12 342.07 16G1 16.14 233.41 421.80 18G1 16.95 274.95 481.02 25G1 19.66 363.99 631.15 29 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 6090602 6090603G 6090603 6090604G 6090604 6090605G 6090605 6090607G 6090607 6090612G 6090612 6090618G 6090625G 6090630G 6090640G 6090802 6090803G 6090803 6090804G 6090804 6090805G 6090805 6090807G 6090807 6090812G 6090812 6090818G 6090818 6090825G 6090834G 6090840G 6090841G 6091002 6091003G 6091003 6091004G 6091004 6091005G 6091007G 6091012G 6091016G 6091018G 6091025G AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=