Flexible cable

Application Product Construction Technical Data Features Wires & Cables ü Conductor : Annealed Plain Copper Conductor as per IEC 60228. ü Insulation : XLPE ü Core Identification acc to DIN 47100 ü Wrapping : Aluminium Mylar Tape ü Braiding : Annealed Tinned Copper Conductor ü Sheath : EBXL- XLPO Halogen free Compound ü Sheath Colour : Grey or as per Customer Order ü With Sequential length marking ü It is used for connecting and interconnecting cable for signaling, control and intercom purposes. ü Used in Telecommunication and information processing system in warehouses, Malls, laboratories, and in other buildings. ü Used in Intercom purposes for paging and intercom systems, clock system, weighing equipment and office machines. ü Cable can laid in wet, dry under plaster, cold places, measuring and concerts. ü Halogen free ü Interference against foreign encoder ü Corrosiveness of combustion gases resistant ü Self-extinguishing and flame retardant ü Reach & RoHS Compliance Siechem Annealed Plain Copper Conductor, XLPE Insulated, ATC Screened & EBXL-XLPO Halogen free Compound Sheathed Cable Part Number Cable Size No. of Cores (Nos) Cross Sectional Area (Sq.mm) Cable Size (AWG) Nom. No.of Strands (Nos) Nom. Strands dia (mm) Construction Nominal Outer Diameter (mm) Approx. Cable Weight (Kg/Km) Max. Conductor DC. Resistance at 20ºC ( Ω /km) 133.9 133.9 133.9 133.9 133.9 133.9 133.9 133.9 133.9 133.9 133.9 133.9 133.9 133.9 133.9 87.6 87.6 87.6 87.6 87.6 87.6 87.6 87.6 87.6 87.6 87.6 21 25 29 34 43 58 67 75 85 97 108 130 145 160 185 24 28 33 41 53 71 82 91 105 118 136 ü Temperature Range : (i) Fixed : -40°C to 90°C (ii) Flexing : -5°C to 90°C ü Operating Voltage : 0.14 mm² = 350 V ≥ 0.25 mm² = 500 V ü Test Voltage : 0.14 mm² = 800 V ≥ 0.25 mm² = 1200 V ü Min. Insulation Resistance : 2 GOhm.km ü Capacitance : core-core < 70 nF/km ü Min. Bending Radius : (i) Flexible : 7.5 x Cable OD (ii) Fixed : 4 x Cable OD ü Max. Coupling Resistance : 250 Ω /km ü Heat Shock at 240°C for 2 hrs ü Halogen-free acc to EN 60754-1 ü Soldering iron resistant and Shall not melt or dip incase of fire ü Corrosiveness of combustion gases acc. to EN 60754-2 ü Flame retardant acc. to EN 60332-1-2 (Outer Sheath) 2 3 4 5 7 10 12 14 16 18 21 25 30 34 40 2 3 4 5 7 10 12 14 16 18 21 VB609A2602 VB609A2603 VB609A2604 VB609A2605 VB609A2607 VB609A2610 VB609A2612 VB609A2614 VB609A2616 VB609A2618 VB609A2621 VB609A2625 VB609A2630 VB609A2634 VB609A2640 B6090302 B6090303 B6090304 B6090305 B6090307 B6090310 B6090312 B6090314 B6090316 B6090318 B6090321 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.193 0.193 0.193 0.193 0.193 0.193 0.193 0.193 0.193 0.193 0.193 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 Sieflame Halogen free Cable 3.9 4.1 4.4 4.6 5.3 6.4 6.8 7.1 7.6 8.2 8.5 9.5 10.0 10.7 11.2 4.1 4.3 4.6 5.0 5.7 7.0 7.4 7.7 8.3 8.8 9.4 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 24 24 24 24 24 24 24 24 24 24 24 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No B609 134 AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=