Flexible cable
111 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No 649 0 Siechem EBXL XLPO 120 C Copper Solar Cable Single Core Copper Conductor Electron Beam Cross Linked Solar Cable as per TUV & UL Specification Construction: Resistance against UV, Water, Ozone, Fluids, Oil, Salt & General Weathering. Electron Beam Cross Linked, Halogen Free, Flame Retardant, Low Smoke emission, Fire retardant to meet IEC 607541-1/EN 50268-2 RoHS compliant as per EU norms Max.Temp. at Conductor Test Voltage Voltage Resistance Test Rated Voltage Short Circuit Temp Features: : 6500V AC : : 600/1000 V AC, 1800 V DC +280°C : EN 50395 Conductor Insulation Jacket : : : Annealed Tinned Copper (APC Optional) according to IEC 60228, Class 5 or as per customer order XLPO Highly weather & UV Resistant (Colour Black or Black with Red strip) 0 XLPO 120 C (Colour Red & Black). Other colours as per customer order Single Core Multi Core Multi Core (EMC) Siechem Solar Cable Range: Type of Solar cables: TUV Siechem Single & Multi Core and Screened Solar cables meets specn.2Pfg 1169/08.2007 UL Dual : : : Siechem Single & Multicore and Screened Solar cables meets UL 4703 Siechem Single & Multicore and Screened cables to meet both TUV & UL specn. : 1.5 to 400sq.mm or its equivalent size in AWG : 2 to 4 cores x 1.5 to 70 sq.mm or its equivalent size in AWG : Up to 61 core screened cables (data sheet against specific request for EMC cables) 0 120 C (20,000h) : Singlecore Solar Cable Max. diameter of wires in Conductor Design Conductor (ATC) 0 DC res at 20 C (max.) Cable Diameter (nom.) Copper Weight (nom.) Cable Weight (nom.) Current Rating Two Cables adjacent on Surfaces Cross Section (nom.) Part Number Sq.mm mm ohm/km mm Kg/Km Kg/Km Amps 1.5 0.26 13.7 4.5 13.0 32.0 24 2.5 0.26 8.21 5.0 21.0 43.0 33 4 0.31 5.09 5.5 33.6 60.0 44 6 0.31 3.39 6.5 51.6 87.0 57 10 0.41 1.95 7.8 85.5 134.0 79 16 0.41 1.24 9.3 140.6 206.0 107 25 0.41 0.795 11.8 218.6 325.0 142 35 0.41 0.565 13.0 307.7 429.0 176 50 0.41 0.393 15.3 427.5 593.0 208 70 0.51 0.277 17.1 608.0 797.0 255 95 0.51 0.210 19.7 802.3 1056.0 306 120 0.51 0.164 21.5 1027.0 1312.0 346 150 0.51 0.132 24.0 1276.8 1629.0 390 185 0.51 0.108 26.6 1561.8 2000.0 436 240 0.51 0.0817 30.0 2061.5 2605.0 507 300 0.51 0.0654 31.7 2621.0 3238.0 571 400 0.51 0.0495 37.4 3485.0 4282.0 649 Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 & Black - 04 * Wires & Cables 64913XX 64916XX 64919XX 64923XX 64927XX 64928XX 64930XX 64932XX 64934XX 64937XX 64938XX 64941XX 64942XX 64944XX 64946XX 64948XX 64949XX 0 Siechem EBXL XLPO 120 C Copper Solar Cable TUV AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=