Fire Resistant cables

Catalogue No. 737 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 28 Part Number 2 Number of Cores and mm Per Conductor Construction Outer Diameter in mm approx. Weight Kg/Km approx. 3 C x 25 3 C x 35 3 C x 50 3 C x 70 3 C x 95 3C x 1 20 3C x 1 50 3C x 1 85 3C x 2 40 3C x 3 00 3C x 4 00 7 x 2. 2 7 x 2. 52 7 x 2. 95 1 9 x 2 .2 19 x 2. 52 19 x 2. 95 19 x 3. 26 37 x 2. 52 37 x 2. 95 37 x 3. 26 61 x 2. 95 2 4. 7 2 6. 8 2 9. 6 3 3. 3 3 8. 1 4 1. 5 4 6. 6 5 0. 9 5 6. 2 6 1. 3 6 7. 7 1 703 2 122 2 660 3 396 4 572 5 489 7 042 8 314 10 25 5 12 48 6 15 77 4 7373003 7373203 7373403 7373703 7373803 7374103 7374203 7374403 7374603 7374803 7374903 Product Construction ü Conductor : APC -Class 2 stranded Copper Conductor. ü Insulation 1 : Mica tape ü Insulation 2 : EBXL - XLPE 120 ü Lay up ü Tape : Mica tape (overall) ü Bedding : Extruded Polymeric mineral ü Armour : GI Wires ü Outer Sheath : Extruded Polymeric mineral Technical Data 0 0 ü Temperature Range : - 45 C to +120 C ü Rated Voltage (U /U) : 600/1000V 0 ü Test Voltage : 600/1000V ü Bending Radius (Min) : Upto 8 x Cable OD Application ü Metro Rail, Airport, Schools, Shopping malls, Cinemas, High-rise Buildings and fire prone areas. ü Indoor and Outdoor uses. Features ü Flammability : IEC 60332-1 & IEC 60332-3 Categories A, B & C ü Resistance to Fire : CWZ of BS : 6387, IEC 60331 & F-2 of BS : 7846 ü Smoke Emission : IEC 61034 - 1 & 2 ü Acid Gas Content : IEC 60754 -1 & 2, BS EN 50267 - 1 & 2 ü Special Features : a) Maintains Circuit Integrity for 3 hours under fire condition. b) Zero Halogen, Low Smoke and Resistance to flame propagation. c) Siechem meets BS 7846 Cat F2 and meets Test requirements as per BS 6387 CWZ, at an enhanced voltage of 600/1000V. Fire Resistant Cable d) Siechem also meets 60 minute rating (PH60) to BS EN 50200 and a 30 minute rating to BS 8434-1. These tests demonstrate that Fire Resistant Cable Fire also meets the requirements for use in “Standard” installations in accordance with BS 5839-1 : 2002 for fire detection and alarm systems, Resistant Cable and Cables with inherently high resistance to attack by fire in accordance with BS 5266-1 : 2005 for emergency lighting. Wires & Cables Siechem, 3 Core APC Class - 2 Conductor, Mica Tape & EBXL - XLPE 120,Insulated GI Wire Armoured Polymeric Mineral Sheath Fire Resistant Cable Siechem 3 coreAPC Stranded GI WireArmoured Polymeric Mineral Sheath Fire Resistant Cable AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=