Fire Resistant cables
Catalogue No. 736 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 27 Wires & Cables Part Number 2 Number of Cores and mm Per Conductor Construction Outer Diameter in mm approx. Weight Kg/Km approx. 5 Cx2 5 5 Cx3 5 5 Cx5 0 5 Cx7 0 7 Cx1 .5 7 Cx2 .5 7 C x4 12 Cx1 .5 12 Cx2 .5 1 2C x4 19 Cx1 .5 19 Cx2 .5 1 9C x4 27 Cx1 .5 27 Cx2 .5 2 7C x4 37 Cx1 .5 37 Cx2 .5 3 7C x4 48 Cx1 .5 48 Cx2 .5 4 8C x4 7 x 2 .14 7 x 2 .52 1 9 x 1.7 8 1 9 x 2.1 4 7 x 0 .53 7 x 0 .67 7 x 0 .85 7 x 0 .53 7 x 0 .67 7 x 0 .85 7 x 0 .53 7 x 0 .67 7 x 0 .85 7 x 0 .53 7 x 0 .67 7 x 0 .85 7 x 0 .53 7 x 0 .67 7 x 0 .85 7 x 0 .53 7 x 0 .67 7 x 0 .85 32 .8 36 .1 41 .7 47 .6 16 .7 18 .6 21 .2 21 .5 24 .5 27 .8 24 .7 29 .1 31 .8 29 .8 33 .8 37 .5 32 .5 36 .3 42 .7 36 .8 43 .4 48 .2 27 06 33 63 45 75 60 64 55 4 69 5 98 4 91 8 11 73 16 39 12 08 17 38 21 66 17 06 22 37 28 37 20 60 27 19 38 52 24 74 36 52 46 86 7363005 7363205 7363405 7363705 7361307 7361607 7361907 7361312 7361612 7361912 7361319 7361619 7361919 7361327 7361627 7361927 7361337 7361637 7361937 7361348 7361648 7361948 Product Construction ü Conductor : APC -Class 2 stranded Copper Conductor. ü Insulation 1 : Mica tape ü Insulation 2 : EBXL - XLPE 120 ü Lay up : ü Tape : Mica tape (overall) ü Bedding : Extruded Polymeric mineral ü Armour : GI Wires ü Outer Sheath : Extruded Polymeric mineral Technical Data 0 0 ü Temperature Range : - 45 C to +120 C ü Rated Voltage (U /U) : 600/1000V 0 ü Test Voltage : 600/1000V ü Bending Radius (Min) : Upto 8 x Cable OD Application ü Metro Rail, Airport, Schools, Shopping malls, Cinemas, High-rise Buildings and fire prone areas. ü Indoor and Outdoor uses. Features ü Flammability : IEC 60332-1 & IEC 60332-3 Categories A, B & C ü Resistance to Fire : CWZ of BS : 6387, IEC 60331 & F-2 of BS : 7846 ü Smoke Emission : IEC 61034 - 1 & 2 ü Acid Gas Content : IEC 60754 -1 & 2, BS EN 50267 - 1 & 2 ü Special Features : a) Maintains Circuit Integrity for 3 hours under fire condition. b) Zero Halogen, Low Smoke and Resistance to flame propagation. c) Siechem meets BS 7846 Cat F2 and meets Test requirements as per BS 6387 CWZ, at an enhanced voltage of 600/1000V. Fire Resistant Cable d) Siechem also meets 60 minute rating (PH60) to BS EN 50200 and a 30 minute rating to BS 8434-1. These tests demonstrate that Fire Resistant Cable Fire also meets the requirements for use in “Standard” installations in accordance with BS 5839-1 : 2002 for fire detection and alarm systems, Resistant Cable and Cables with inherently high resistance to attack by fire in accordance with BS 5266-1 : 2005 for emergency lighting. Siechem, Multicore APC Class - 2 Conductor, Mica tape & EBXL - XLPE 120,Insulated GI Wire Armoured Polymeric Mineral Sheath Fire Resistant Cable Siechem ,Multicore APCStranded GIWire Armoured Polymeric mineralSheathFireResistantCable AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=