Fire Resistant cables
Wires & Cables Product Construction ü Conductor : Annealed Copper conductor, Class 2 Stranded conductor. ü Insulation 1 : Glass Mica tape. 0 ü Insulation 2 : EBXL-XLPE-120 C. ü Insulation 3 : Glass Mica tape. ü Inner Sheath : XLPO ü Outer Sheath : XLPO Application 2 Number of Cores and mm Per Conductor Part Number Outer Diameter in mm approx. Weight Kg/Km approx. Conductor Construction Min Max 7321002 7321302 7321602 7321902 7322302 7322702 7322802 7323002 7323202 7321003 7321303 7321603 7321903 7322303 7322703 7322803 7323003 7323203 7321004 7321304 7321604 7321904 7322304 7322704 7322804 7323004 ü Metro Rail, Airport, Schools, Shopping malls, Cinemas, High-rise Buildings and fire prone areas. ü Indoor and Outdoor uses. Thermosetting Insulated, Multi core, XLPO Sheathed Fire Resistant Cables, 450/750 V Technical Data o o ü Temperature Range :-15 C to + 120 C ü Rated Voltage (U /U) : 450/750 V 0 ü Test Voltage : 3.5kV/5 min ü Bending Radius (Min) :Upto 8 X cable OD ü Specification : BS 7211, Table - 6 Features ü Flammability : IEC 60332-1 & IEC 60332-3 Categories A, B & C ü Resistance to Fire : CWZ of BS : 6387, IEC 60331 & F-2 of BS : 7846 ü Smoke Emission : IEC 61034 - 1 & 2 ü Acid Gas Content : IEC 60754 -1 & 2, BS EN 50267 - 1 & 2 ü Special Features : a) Maintains Circuit Integrity for 3 hours under fire condition. b) Zero Halogen, Low Smoke and Resistance to flame propagation. c) Siechem meets BS 7846 Cat F2 and meets Test requirements as per BS 6387 CWZ, at an enhanced voltage of 600/1000V. Fire Resistant Cable d) Siechem also meets 60 minute rating (PH60) to BS EN 50200 and a 30 minute rating to BS 8434-1. These tests demonstrate that Fire Resistant Cable Fire also meets the requirements for use in “Standard” installations in accordance with BS 5839-1 : 2002 for fire detection and alarm systems, Resistant Cable and Cables with inherently high resistance to attack by fire in accordance with BS 5266-1 : 2005 for emergency lighting. 188 211 251 307 375 536 736 1043 1339 210 238 289 360 463 648 905 1302 1690 241 276 338 428 572 785 1109 1635 9.7 10.3 11.3 12.4 13.7 16.7 18.8 23.2 26.0 10.2 10.9 11.9 13.1 15.0 17.5 19.9 24.7 27.6 9.7 10.3 11.3 12.4 13.7 16.7 18.8 23.2 8.1 8.5 9.3 10.3 11.3 13.8 15.6 19.2 21.5 8.8 9.0 9.8 10.8 12.4 14.6 16.5 20.4 22.9 8.1 8.5 9.3 10.3 11.3 13.8 15.6 19.2 7 X 0.44 7 X 0.53 7 X 0.67 7 X 0.85 7 X 1.04 7 X 1.35 7 X 1.7 7 X 2.14 7 X 2.52 7 X 0.44 7 X 0.53 7 X 0.67 7 X 0.85 7 X 1.04 7 X 1.35 7 X 1.7 7 X 2.14 7 X 2.52 7 X 0.44 7 X 0.53 7 X 0.67 7 X 0.85 7 X 1.04 7 X 1.35 7 X 1.7 7 X 2.14 2C x 1 2C x 1.5 2C x 2.5 2C x 4 2C x 6 2C x 10 2C x 16 2C x 25 2C x 35 3C x 1 3C x 1.5 3C x 2.5 3C x 4 3C x 6 3C x 10 3C x 16 3C x 25 3C x 35 4C x 1 4C x 1.5 4C x 2.5 4C x 4 4C x 6 4C x 10 4C x 16 4C x 25 Catalogue No. 732 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 22 Siechem Multicore APC Stranded Unarmourd Fire Resistant 450/750 V Rated Cable AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=