Fire Resistant cables
Catalogue No. 731 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 21 Product Construction ü Conductor : Annealed Copper conductor, Class 1 solid conductor. ü Insulation 1 : Glass Mica tape. 0 ü Insulation 2 : EBXL-XLPE-120 C. ü Insulation 3 : Glass Mica tape. ü Inner Sheath : XLPO ü Outer Sheath : XLPO Application 2 Number of Cores and mm Per Conductor Part Number Wires & Cables Outer Diameter in mm approx. Weight Kg/Km approx. Conductor Construction Min Max 2C x 1 2C x 1.5 2C x 2.5 2C x 4 2C x 6 2C x 10 3C x 1 3C x 1.5 3C x 2.5 3C x 4 3C x 6 3C x 10 4C x 1 4C x 1.5 4C x 2.5 4C x 4 4C x 6 4C x 10 5C x 1 5C x 1.5 5C x 2.5 5C x 4 5C x 6 5C x 10 1 X 1.13 1 X 1.38 1 X 1.77 1 X 2.24 1 X 2.74 1 X 3.56 1 X 1.13 1 X 1.38 1 X 1.77 1 X 2.24 1 X 2.74 1 X 3.56 1 X 1.13 1 X 1.38 1 X 1.77 1 X 2.24 1 X 2.74 1 X 3.56 1 X 1.13 1 X 1.38 1 X 1.77 1 X 2.24 1 X 2.74 1 X 3.56 7.9 8.4 9.1 10.0 10.9 12.9 8.3 8.8 9.6 10.5 11.8 14.0 7.9 8.4 9.1 10.0 10.9 12.9 7.9 8.4 9.1 10.0 10.6 12.9 9.5 10.1 11.0 12.1 13.2 15.5 10.0 10.6 11.6 12.7 14.0 16.9 9.5 10.1 11.0 12.1 13.2 15.5 9.5 10.1 11.0 12.1 13.2 15.5 179 200 238 290 354 489 200 227 275 342 425 616 229 263 323 408 529 749 262 303 377 496 644 894 7311002 7311302 7311602 7311902 7312302 7312702 7311003 7311303 7311603 7311903 7312303 7312703 7311004 7311304 7311604 7311904 7312304 7312704 7311005 7311305 7311605 7311905 7312305 7312705 ü Metro Rail, Airport, Schools, Shopping malls, Cinemas, High-rise Buildings and fire prone areas. ü Indoor and Outdoor uses. Thermosetting Insulated, Multi core, XLPO Sheathed Fire Resistant Cables, 450/750 V Technical Data o o ü Temperature Range :-15 C to + 120 C ü Rated Voltage (U /U) : 450/750 V 0 ü Test Voltage : 3.5kV/5 min ü Bending Radius (Min) :Upto 8 X cable OD ü Specification : BS 7211,Table - 6 Features ü Flammability : IEC 60332-1 & IEC 60332-3 Categories A, B & C ü Resistance to Fire : CWZ of BS : 6387, IEC 60331 & F-2 of BS : 7846 ü Smoke Emission : IEC 61034 - 1 & 2 ü Acid Gas Content : IEC 60754 -1 & 2, BS EN 50267 - 1 & 2 ü Special Features : a) Maintains Circuit Integrity for 3 hours under fire condition. b) Zero Halogen, Low Smoke and Resistance to flame propagation. c) Siechem meets BS 7846 Cat F2 and meets Test requirements as per BS 6387 CWZ, at an enhanced voltage of 600/1000V. Fire Resistant Cable d) Siechem also meets 60 minute rating (PH60) to BS EN 50200 and a 30 minute rating to BS 8434-1. These tests demonstrate that Fire Resistant Cable Fire also meets the requirements for use in “Standard” installations in accordance with BS 5839-1 : 2002 for fire detection and alarm systems, Resistant Cable and Cables with inherently high resistance to attack by fire in accordance with BS 5266-1 : 2005 for emergency lighting. Siechem MulticoreAPC Solid Unarmoured Fire Resistant 450/750/V Rated Cable AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=