Fire Resistant cables
Catalogue No. 725 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 15 Wires & Cables Product Construction ü Conductor : Annealed Copper conductor, Class 2 Stranded conductor. ü Insulation 1 : Glass Mica tape. 0 ü Insulation 2 : EBXL-XLPE-120 C. Application 2 Number of Cores and mm Per Conductor Part Number Outer Diameter in mm approx. Weight Kg/Km approx. Conductor Construction Min Max 1C x 1.5 1C x 2.5 1C x 4 1C x 6 1C x 10 1C x 16 1C x 25 1C x 35 1C x 50 1C x 70 1C x 95 1C x 120 1C x 150 1C x 185 1C x 240 1C x 300 1C x 400 1C x 500 1C x 630 7 X 0.53 7 X 0.67 7 X 0.85 7 X 1.04 7 X 1.35 7 X 1.7 7 X 2.14 7 X 2.52 19 X 1.78 19 X 2.14 19 X 2.52 37 X 2.03 37 X 2.25 37 X 2.52 61 X 2.25 61 X 2.52 61 X 2.85 61 X 3.2 127 X 2.52 25 38 54 75 121 184 279 377 532 723 976 1212 1511 1871 2411 3006 3965 4931 6160 25 38 54 75 121 184 279 377 532 723 976 1212 1511 1871 2411 3006 3965 4931 6160 3.4 4.1 4.7 5.4 7.0 8.0 10.1 11.3 13.2 15.1 17.6 19.4 21.6 24.1 27.5 30.6 34.3 38.2 42.5 72513XX 72516XX 72519XX 72523XX 72527XX 72528XX 72530XX 72532XX 72534XX 72537XX 72538XX 72541XX 72542XX 72544XX 72546XX 72548XX 72549XX 72550XX 72551XX ü Metro Rail, Airport, Schools, Shopping malls, Cinemas, High-rise Buildings and fire prone areas. ü Indoor and Outdoor uses. Thermosetting Insulated, Non Sheathed, Single core H07Z-R Fire Resistant Cable, 450/750 V Technical Data o o ü Temperature Range :-15 C to + 120 C ü Rated Voltage (U /U) : 450/750 V 0 ü Test Voltage : 3.5kV/5 min ü Bending Radius (Min) :Upto 8 X cable OD ü Specification : BS 7211,Table - 3 Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 Features ü Flammability : IEC 60332-1 & IEC 60332-3 Categories A, B & C ü Resistance to Fire : CWZ of BS : 6387, IEC 60331 & F-2 of BS : 7846 ü Smoke Emission : IEC 61034 - 1 & 2 ü Acid Gas Content : IEC 60754 -1 & 2, BS EN 50267 - 1 & 2 ü Special Features : a) Maintains Circuit Integrity for 3 hours under fire condition. b) Zero Halogen, Low Smoke and Resistance to flame propagation. c) Siechem meets BS 7846 Cat F2 and meets Test requirements as per BS 6387 CWZ, at an enhanced voltage of 600/1000V. Fire Resistant Cable d) Siechem also meets 60 minute rating (PH60) to BS EN 50200 and a 30 minute rating to BS 8434-1. These tests demonstrate that Fire Resistant Cable Fire also meets the requirements for use in “Standard” installations in accordance with BS 5839-1 : 2002 for fire detection and alarm systems, Resistant Cable and Cables with inherently high resistance to attack by fire in accordance with BS 5266-1 : 2005 for emergency lighting. Siechem Single Core H07Z-R Fire Resistant 450/750 V Rated Cable AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=