Fire Resistant cables

Area 2 mm Approximate Overall Diameter mm Approximate Diameter under Armour mm Nominal Diameter of Armour wires mm Approximate Cable Weight Kg/km Maximum Conductor Resistance at 0 20 C ohms/km 0 Current Rating for 120 C Operating Temperature Voltage Drop Single Phase AC mV/A/m Application Technical Data Wires & Cables 0 0 ü Temperature Range : -15 C to +120 C ü Rated Voltage (U /U) : 600/1000V 0 ü Test Voltage : 3.5kV/5 min ü Bending Radius : Upto 8 of Cable X OD ü Specification : BS 7846 & BS 6387 Enhanced Electron Beam Cross Linked Armoured Fire Resistant Cables - FRX 400+ Core Identification ExistingColourCode NewHarmonisedColourCode Single Phase Three Phase ü Metro Rail, Airport, Schools, Shopping malls, Cinemas, High-rise Buildings and fire prone areas. ü Indoor and Outdoor uses. Red Black Red Yellow Blue Black Brown Blue Brown Black Grey Blue 0.9 0.9 0.9 0.9 0.9 0.9 1.25 1.6 1.6 1.6 2.0 2.0 2.0 2.5 2.5 2.5 2.5 8.3 9.6 10.6 12.0 14.0 15.9 18.3 20.9 21.2 23.7 27.3 28.4 30.9 34.4 38.0 41.6 45.3 12.9 14.1 15.2 16.4 18.6 21.4 23.7 27.2 28.0 30.7 35.3 36.6 39.3 44.2 48.0 51.8 55.9 310 380 450 530 630 920 1200 1600 2000 2400 3300 3800 4400 5700 7200 8300 10500 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.047 31.0 19.0 12.0 7.9 4.7 2.9 1.90 1.35 1.00 0.69 0.52 0.42 0.35 0.29 0.24 0.21 0.19 Direct in Ground Amps Amps In Duct In Air Amps Product Construction Fire Resistant Cable Construction CopperConductor Dual Insulation -MicaGlass -XLPE LSFBedding (LowSmoke&Fume.Also known as LowSmokeZero halogen -LSZH) Core Identification - Standard Red -Black Red -Yellow Blue Red -Yellow -Blue -Black Brown -Blue Brown -Black -Grey Blue -Brown -Black -Grey -Alternative * Features ü Flammability : IEC 60332-1 & IEC 60332-3 Categories A, B & C ü Resistance to Fire : CWZ of BS : 6387, IEC 60331 & F-2 of BS : 7846 ü Smoke Emission : IEC 61034 - 1 & 2 ü Acid Gas Content : IEC 60754 -1 & 2, BS EN 50267 - 1 & 2 ü Special Features : a) Maintains Circuit Integrity for 3 hours under fire condition. b) Zero Halogen, Low Smoke and Resistance to flame propagation. c) Siechem FRX 400+ meets BS 7846 Cat F2 and meets Test requirements as per BS 6387 CWZ, at an enhanced voltage of 600/1000V. d) Siechem FRX 400+ also meets 60 minute rating (PH60) to BS EN 50200 and a 30 minute rating to BS 8434-1. These tests demonstrate that FRX 400+ also meets the requirements for use in “Standard” installations in accordance with BS 5839-1 : 2002 for fire detection and alarm systems, and Cables with inherently high resistance to attack by fire in accordance with BS 5266-1 : 2005 for emergency lighting. GalvanisedSteelwire armoured LSFOuterSheath 1.5 2.5 4 6 10 16 25 35 50 0.9 0.9 0.9 0.9 1.25 1.25 1.6 1.6 1.6 8.8 10.2 11.5 12.8 14.8 17.1 20.8 22.4 26.2 13.4 14.8 16.1 17.4 20.3 22.8 27.4 29.2 33.0 340 430 510 620 930 1210 1800 2100 2600 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 27.0 16.0 10.0 6.8 4.0 2.5 1.65 1.15 0.87 Area 2 mm Approximate Overall Diameter mm Approximate Diameter under Armour mm Nominal Diameter of Armour wires mm Approximate Cable Weight Kg/km Maximum Conductor Resistanc at 0 20 C ohms/km 0 Current Rating for 120 C Operating Temperature 0 (Calculated for 40 C Ambient Air Temperature) Voltage Drop Three Phase AC mV/A/m Direct in Ground Amps Amps In Duct In Air Amps Short Circuit Rating (1 sec) of onductor KA 0.20 0.35 0.57 0.86 1.4 2.2 3.6 5.0 7.1 10.0 13.6 17.2 21.4 26.5 34.3 42.9 57.2 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 43 56 73 92 120 151 198 234 273 343 408 451 511 576 660 745 803 39 51 65 83 108 135 178 211 255 309 368 417 472 530 606 683 770 38 51 65 79 104 134 173 203 281 317 387 432 495 576 680 770 872 33 44 57 72 95 126 159 190 224 30 40 52 65 86 113 143 170 202 29 39 52 65 82 117 143 182 211 0.20 0.35 0.57 0.86 1.4 2.2 3.6 5.0 7.1 1 2 3 4 5 Siechem EBXL FRX 400 + Unarmourd Fire Resistant Cables Part Number Two Core Three Core 7221302 7221602 7221902 7222302 7222702 7222802 7223002 7223202 7223402 7223702 7223802 7224102 7224202 7224402 7224602 7224802 7224902 7221303 7221603 7221903 7222303 7222703 7222803 7223003 7223203 7223403 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 12 AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=