Fire Resistant cables

Wires & Cables Application Technical Data 0 0 ü Temperature Range : -15 C to +120 C ü Rated Voltage (U /U) : 600/1000V 0 ü Test Voltage : 3.5kV/5 min ü Bending Radius : Upto 8 of Cable X OD ü Specification : Gen. BS 7846 & BS 6387 Enhanced Electron Beam Cross Linked Unarmoured Fire Resistant Cables - FRX 200+ ü Metro Rail, Airport, Schools, Shopping malls, Cinemas, High-rise Buildings and fire prone areas. ü Indoor and Outdoor uses. Product Construction Features ü Flammability : IEC 60332-1 & IEC 60332-3 Categories A, B & C ü Resistance to Fire : CWZ of BS : 6387, IEC 60331 & F-2 of BS : 7846 ü Smoke Emission : IEC 61034 - 1 & 2 ü Acid Gas Content : IEC 60754 -1 & 2, BS EN 50267 - 1 & 2 ü Special Features : a) Maintains Circuit Integrity for 3 hours under fire condition. b) Zero Halogen, Low Smoke and Resistance to flame propagation. c) Siechem FRX 200+ meets BS 7846 Cat F2 and meets Test requirements as per BS 6387 CWZ, at an enhanced voltage of 600/1000V. d) Siechem FRX 200+ also meets 60 minute rating (PH60) to BS EN 50200 and a 30 minute rating to BS 8434-1. These tests demonstrate that FRX 200+ also meets the requirements for use in “Standard” installations in accordance with BS 5839-1 : 2002 for fire detection and alarm systems, and Cables with inherently high resistance to attack by fire in accordance with BS 5266-1 : 2005 for emergency lighting. ü Conductor : Plain annealed Copper solid or stranded circular conductor complying with BS 6360 class 1 or 2. ü Insulation : Dual Insulation Mica Glass - XLPE ü Bedding : Polymeric LSOH Material ü Outer Sheath : Robust Polymeric LSOH Material Siechem EBXL FRX 200+ Unarmourd Fire Resistant Cables Area 2 mm Approximate Overall Diameter mm Approximate Diameter under Armour mm Nominal Diameter of Armour wires mm Approximate Cable Weight Kg/km Maximum Conductor Resistance at 0 20 C ohms/km 0 Current Rating for 120 C Operating Temperature Voltage Drop Single Phase AC mV/A/m Direct in Ground Amps Amps In Duct In Air Amps Three Core Area 2 mm Approximate Ov all Diamet r m Approximate Cable Weight Kg/km Maximum Conductor Resistance at 0 20 C ohms/km 0 Current Rating for 120 C Operating Temperature 0 (Calculated for 40 C Ambient Air Temperature) Voltage Drop DC or Single Phase AC mV/A/m Direct in Ground A ps Amps I Duct In Air Amps Short Circuit Rating (1 sec) of onductor KA Three Core Two Core Four Core 1.0 1.5 2.5 4 18.1 12.1 7.41 4.61 44 29 18 11 1.0 1.5 2.5 4 18.1 12.1 7.41 4.61 44 29 18 11 44 29 18 11 1.0 1.5 2.5 4 18.1 12.1 7.41 4.61 34 43 56 73 25 33 44 57 25 33 44 57 31 39 51 65 31 38 51 65 22 30 40 52 21 29 39 52 22 30 40 52 21 29 39 52 0.14 0.20 0.35 0.57 0.14 0.20 0.35 0.57 0.14 0.20 0.35 0.57 10.3 10.8 11.6 13.1 135 154 188 248 10.7 11.3 12.1 13.8 150 172 215 287 11.4 12.1 13.0 14.9 170 198 251 340 Part Number 7191002 7191302 7191602 7191902 7191003 7191303 7191603 7191903 7191004 7191304 7191604 7191904 Catalogue No. 719 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 11 AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=