Diesel Locomotive Cables

Catalogue No. www.siechem.com Application Product Construction 2D View Technical Data Outer Diameter (Nom.) (Inches) 18 AWG 18 AWG 16 AWG 16 AWG 16 AWG 14 AWG 14 AWG 12 AWG 12 AWG 8 AWG 5 AWG 3 AWG 1 AWG 2/0 AWG 4/0 AWG 313 MCM 535 MCM 597 MCM 10 AWG 20 AWG 20 AWG 2/0 AWG 1 AWG 535 MCM 646 MCM 444 MCM 597 MCM 4/0 AWG 777 MCM 19/30 19/30 19/29 19/29 19/29 37/29 37/29 37/27 37/27 37/24 91/24 125/24 225/24 325/24 550/24 775/24 1325/24 1480/24 27/24 19/32 19/32 325/24 225/24 1325/24 1600/24 1100/24 1480/24 2109/24 1924/24 0.030 0.030 0.030 0.030 0.045 0.030 0.0435 0.030 0.045 0.055 0.055 0.055 0.065 0.065 0.105 0.105 0.125 0.125 0.045 0.015 0.029 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 11.1 11.1 14.5 14.5 18.8 21.6 25.6 31.4 36.9 71.0 158 206 365 494 872 1216 2033 2186 51.0 5.39 8.0 552 408 1892 2222 1479 2105 855 2795 Yellow Green Red Green Orange White LT Grey LT Blue Blue DK Grey DK Grey DK Grey DK Grey DK Grey DK Grey DK Grey DK Grey DK Grey DK Grey Brown Tan DK Grey DK Grey DK Grey DK Grey DK Grey DK Grey Grey DK Grey 17 17 25 25 25 40 40 50 50 90 155 190 280 355 490 610 850 900 70 5 5 355 280 849 954 757 902 481 1080 9094883 Wires & Cables 0 Siechem Diesel Electric Locomotive Cables ATC, 125 C, As per EMD/9094883, upto 2100V All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 12 ü Conductor : Annealed Tinned Copper Flexible Conductor. ü Insulation : Dual Layer Thermosetting Irradiation Cross Linked Polyolefin as per EDPS179/304 ü Inner Layer : EPDM ü Outer Layer : CPE Features ü Excellent resistance to high and low temperature ü Outstanding flame retardant ü Halogen free ü Excellent flexibility ü Resistance to Oil, Fuel, Ozone and Weathering. ü Easy to strip ü Low smoke density ü Soldering iron resistant ü Electron Beam Cross Linked. 0 Siechem EMD/9094883 ATC, 125 C Diesel Electric Locomotive Cables 0 0 ü Temperature Range : -65 C to +125 C 0 ü Thermal Life Rating : >10000 hrs @ +125 C. ü Specification: EDPS 179 & 304 - 9094883 0.111 0.111 0.122 0.122 0.152 0.139 0.165 0.159 0.189 0.261 0.359 0.407 0.530 0.620 0.847 0.963 1.245 1.300 0.218 0.071 0.100 0.690 0.620 1.145 1.270 1.080 1.205 0.825 1.404 EMD Part Number Conductor Size (AWG/MCM) No of Strands /Strand dia (Nos/AWG) Insulation Thickness (Nom) (Inches) Weight (Approx) (LBS/1000FT) Insulation Colour N.E.C 30°C Single Conductor Free Air Ampacity (A) EDPS Specification Voltage Rating AC (V) 179 179 179 179 179 179 179 179 179 179 179 179 304 304 304 304 304 304 179 179 179 304 304 304 304 304 304 304 304 600 600 600 600 2000 600 1500 600 2000 2000 2000 2000 2000 2000 2100 2100 2100 2100 2000 600 600 2100 2100 2100 2100 2100 2100 2100 2100 ü Developed to supply power to traction motors of the diesel-electric locomotives ü Portable cable for drilling rigs, on-shore and off- shore applications, railroad and transit car wiring, and electric earth-moving equipment ü Well-suited for other applications like shipyards, power and control jumper cables, motor leads, and sometimes as a telecom power supply. ü At times as a welding cable,especially for high-current applications. 8466845-G 9321021-F 8466844-F 9322292-E 9086254-E 8470754-F 8460546-H 40019384-B 8460547-G 9094884-G 9094885-G 9094886-G 9094887-G 9094888-G 9094889-H 9094890-H 8462288-H 9085669-H 9530744-C 8408649-H 40028092-E 40085782-C 10661360-C 40015786-E 40015787-E 40038694-D 40036094-D 40056040-D 40116622-C IndianRailways RDSO AS 9100 ISO 14001 ISO 9001 ISO 45001

RkJQdWJsaXNoZXIy NDgyMjA=