Automotive cable
Application Product Construction Technical Data Wires & Cables Auto 125- TW Features ü Low-tension electric wire for automobiles. ü Used in motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Especially used for circuits requiring heat resistance. Wires & Cables A811 Siechem Auto 125 - TW RoHS 81 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Nominal Cross- Section No. of Strands Diameter of Single wire max. Conductor Construction Conductor Diameter max. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness Nom. 2 mm nos. mm mtrs kg/km mm Standard Length* Part Number mm mm Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 o o ü Current Carrying capacity given is for the maximum conductor operating of 125 C and ambient air temperature of 40 C. ü Cables are also available in dual colored insulation ü * Other length as per Customer order. * Max. Conductor Resistance 0 at 20 C Ω/km Class A B C D E F G H o o o o o o o o +85 C +100 C +125 C +150 C +175 C +200 C +225 C +250 C Temperature o from -40 C to Nominal Cross- Section No. of Strands Diameter of Single wire Max. Conductor Construction Conduct r Diameter Max. Cable Overall Diameter Weight Approx. Max. Insulatio Wall Thickness Nom. Standard Length* * Max. Conductor Resistanc 0 at 20 C Class A B C D E F H 0.35 0.50 0.75 1 1.5 2 2.5 3 4 5 6 10 16 25 7 19 19 19 19 19 37 37 37 37 37 63 105 154 0.27 0.19 0.24 0.27 0.33 0.38 0.28 0.34 0.38 0.43 0.45 0.46 0.46 0.46 0.90 1.10 1.30 1.50 1.80 2.00 2.20 2.40 2.80 3.10 3.40 4.50 6.30 7.80 0.25 0.28 0.30 0.30 0.30 0.35 0.35 0.40 0.40 0.40 0.40 0.60 0.65 0.65 1.40 1.60 1.90 2.10 2.40 2.80 3.00 3.40 3.70 4.20 4.30 6.00 7.20 8.70 5 6 9 11 17 23 26 34 42 53 60 106 177 249 54.4 37.1 24.7 18.5 12.7 9.42 7.60 6.15 4.71 3.94 3.14 1.82 1.16 0.743 2000 2000 2000 2000 2000 2000 2000 1000 1000 1000 1000 1000 1000 1000 A81105XX A81106XX A81108XX A81110XX A81113XX A81114XX A81116XX A81117XX A81119XX A81121XX A81123XX A81127XX A81128XX A81130XX Cables confirming to the below categories are also available according to customer requirement Conductor Configuration : Symmetrical, Asymmetrical, Flexible Insulation thickness : Standard, Thin wall & Ultra thin wall ISO 6722 Temperature Class Rating : ü Conductor : Soft /annealed Plain Copper according to ISO 6722 (Symmetrical) ü Insulation : Electron beam crossed Linked Polyolefin Class C ü Colour : As per customer order ü Cable construction according to ISO 6722, Class C (Thin wall) ü Single core, Single layer insulation 0 0 ü Temperature Range: -40 C to +125 C (3000 Hours) ü Standard : ISO 6722 Class C (Thin wall) ü Operating Voltage : (i) (60 V DC (or) 25 V AC) (or) (ii) (600V DC (or) 600 V AC) 2 ü Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm 2 5kV (r.m.s.) for cables ≥ 0.5 mm ü Excellent Flame retardant ü Highly resistant against acids, alkali, petrol and diesel ü Extra flexible conductors with Electron beam cross linked polyolefin thin wall insulation for smaller diameter and lesser weight ü Excellent flexibility ü Heat resistant ü Halogen free Current Carrying capacity Amps 12 15 19 23 30 37 42 48 57 65 71 104 140 261 Catalogue No Siechem Wires & Cables Meet EU RoHS Directive AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=