Automotive catalogue

Catalogue No A808 www.siechem.com 81 Nominal Cross- Section No. of Strands Diameter of Single wire Max. Conductor Construction Conductor Diameter Max. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness Nom. 2 mm nos. mm mtrs kg/km mm Standard Length* Part Number mm mm * Max. Conductor Resistance 0 at 20 C Ω/km 0.35 0.50 0.75 1 1.5 2 2.5 3 4 5 6 10 0.25 0.28 0.30 0.30 0.30 0.35 0.35 0.40 0.40 0.40 0.40 0.60 1.40 1.60 1.90 2.10 2.40 2.80 3.00 3.40 3.70 4.20 4.30 6.00 54.4 37.1 24.7 18.5 12.7 9.42 7.60 6.15 4.71 3.94 3.14 1.82 2000 2000 2000 2000 2000 2000 2000 1000 1000 1000 1000 1000 12 16 24 32 30 28 50 44 56 65 84 80 0.21 0.21 0.21 0.21 0.26 0.31 0.26 0.31 0.31 0.33 0.31 0.41 5 6 9 12 17 23 26 34 42 53 60 106 0.90 1.10 1.30 1.50 1.80 2.00 2.20 2.40 2.80 3.10 3.40 4.50 A80805XX A80806XX A80808XX A80810XX A80813XX A80814XX A80816XX A80817XX A80819XX A80821XX A80823XX A80827XX Current Carrying Capacity Amps 12 16 22 26 33 41 46 54 64 72 82 119 Application Product Construction Technical Data Wires & Cables 2D View Siechem FLR91X-B Class D RoHS 0 0 ü Temperature Range: -40 C to +150 C (3000 Hours) ü Standard : ISO 6722-1 Class D (Thin wall) 2 ü Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm 2 5kV (r.m.s.) for cables ≥ 0.5 mm FLR91X-B Features ü Low-tension electric wire for Automobiles. ü Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Especially used for requiring heat resistance ü Conductor : Soft / annealed Plain Copper according to ASTM B3 ü Insulation : Electron Beam Cross Linked Polyolefin ü Colour : As per customer order ü Cable construction according to ISO 6722-1, Class D (Thin wall) ü Single core, Single layer insulation Wires & Cables ü Unilay conductor PVC ü Thin wall insulation ü Saving of insulation material, resulting in substantial weight reduction ü Heat resistance ü Halogen free Siechem Wires & Cables Meet EU RoHS Directive Automotive Cables All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any other compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Progress throughResearch R TUV ** Certifications Approvals Accreditations ResearchDesign&StandardsOrganisation 2D View

RkJQdWJsaXNoZXIy NDgyMjA=