Automotive catalogue
Catalogue No A814 www.siechem.com 79 Application Product Construction Technical Data Wires & Cables 2D View Siechem FLR91X-A Class D RoHS 0 0 ü Temperature Range: - 40 C to +150 C (3000 Hours). ü Standard : ISO 6722-1 Class D (Thin wall) 2 ü Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm 2 5kV (r.m.s.) for cables ≥ 0.5 mm ü Low-tension electric wire for Automobiles. ü Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Especially used for requiring heat resistance ü Conductor : Soft / Annealed Plain Copper according to ASTM B3 ü Optional : Tinned Copper Conductor ü Insulation : Electron Beam Cross Linked Polyolefin ü Colour : As per customer order ü Cable construction according to ISO 6722-1, Class D (Thin wall) ü Single core, Single layer insulation Wires & Cables Nominal Cross- Section No. of Strands Diameter of Single wire Max. Conductor Construction Conductor Diameter Max. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness Nom. 2 mm nos. mm mtrs kg/km mm Standard Length* Part Number mm mm * Max. Conductor Resistance 0 at 20 C Ω/km 0.35 0.50 0.75 1 1.5 2 2.5 3 4 5 6 10 16 0.25 0.28 0.30 0.30 0.30 0.35 0.35 0.40 0.40 0.40 0.40 0.60 0.65 1.30 1.60 1.90 2.10 2.40 2.80 3.00 3.40 3.70 4.20 4.30 6.00 7.20 54.4 37.1 24.7 18.5 12.7 9.42 7.60 6.15 4.71 3.94 3.14 1.82 1.16 2000 2000 2000 2000 2000 2000 2000 1000 1000 1000 1000 1000 1000 7 19 19 19 19 19 37 37 37 37 37 63 105 0.27 0.19 0.24 0.27 0.33 0.38 0.28 0.34 0.38 0.43 0.45 0.46 0.46 5 6 9 12 17 23 26 34 42 53 60 106 165 0.90 1.10 1.30 1.50 1.80 2.00 2.20 2.40 2.80 3.10 3.40 4.50 5.80 A81405XX A81406XX A81408XX A81410XX A81413XX A81414XX A81416XX A81417XX A81419XX A81421XX A81423XX A81427XX A81428XX Features ü Unilay conductor PVC ü Thin wall insulation ü Saving of insulation material, resulting in substantial weight reduction ü Heat resistance ü Halogen free Current Carrying Capacity Amps 12 16 22 26 33 41 46 54 64 72 82 119 158 FLR91X-A Automotive Cables All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any other compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Progress throughResearch R TUV ** Certifications Approvals Accreditations ResearchDesign&StandardsOrganisation 2D View
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=