Automotive catalogue

Application Product Construction Technical Data Wires & Cables 2D View 0 0 ü Temperature Range: -40 C to +100 C (3000 Hours) ü Standard : ISO 6722 Class B 2 ü Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm 2 5kV (r.m.s.) for cables ≥ 0.5 mm ü Low-tension electric wire for Automobiles. ü Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Conductor : Soft / annealed Plain Copper according to ISO 6722 (Symmetrical) ü Insulation : PVC with properties according to ISO 6722 Class B, Lead free ü Colour : As per customer order ü Cable construction according to ISO 6722, Class B ( Ultra Thin wall) ü Single core, Single layer insulation Wires & Cables Nominal Cross- Section No. of Strands Diameter of Single wire max. Conductor Construction Conductor Diameter max. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness Nom. 2 mm nos. mm mtrs kg/km mm Standard Length* Part Number mm mm Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 o o ü Current Carrying capacity given is for the maximum conductor operating of 100 C and ambinet air temperature of 40 C. ü * Other length as per Customer order. ** We have obtained various approvals, accreditations, and certifications — some of which may not be relevant to this catalog. * Max. Conductor Resistance 0 at 20 C Ω/km A833 www.siechem.com Siechem Auto 100 UTW Class B RoHS Features ü Unilay conductor Stranding ü Reduced diameter / Very thin wall thickness ü Saving of insulation material, resulting in Substantial Weight reduction Nominal Cross- Section No. of Strands Diameter of Single wir max. Conductor Construction Conductor Diameter max. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness Nom. St ndard Length* * Max. Conductor Resistance 0 at 20 C Catalogue No 0.50 0.75 1 1.5 2 2.5 1.10 1.30 1.50 1.80 2.00 2.20 0.20 0.20 0.20 0.20 0.25 0.25 1.40 1.60 1.75 2.10 2.40 2.70 6 8 10 15 20 24 500 500 500 500 500 500 A83306XX A83308XX A83310XX A83313XX A83314XX A83316XX 37.1 24.7 18.5 12.7 9.42 7.60 Current Carrying Capacity Amps 14 17 19 25 31 36 19 19 19 19 19 37 0.19 0.24 0.27 0.33 0.38 0.28 74 Auto 100 TW Auto 100 - U Automotive Cables All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any other compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Progress throughResearch R TUV ** Certifications Approvals Accreditations ResearchDesign&StandardsOrganisation 2D View

RkJQdWJsaXNoZXIy NDgyMjA=