Automotive cable

Application Product Construction Technical Data Wires & Cables 2D View Siechem SGX RoHS ü Temperature Range : 0 0 - 40 C to +125 C (3000 Hours) ü Standard : SAE J1127 ü Test Voltage : 1 kV ü S :Starter or Ground ü G : General purpose ü X : Cross linked polyolefin Nominal Cross- Section No. of Strands Diameter of Single wire max. Conductor Construction Conductor Diameter Nom. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness 2 mm nos. mm mm mtrs kg/km mm Standard Length* Part Number Current Carrying Capacity mm mm Amps 133 133 133 259 1026 1254 1615 2052 0.36 0.46 0.57 0.46 0.26 0.26 0.26 0.26 4.83 6.09 7.67 8.49 9.47 10.47 11.89 13.40 SGX Features ü Wire harness of low-tension electric circuts for automobiles. ü Used in motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Especially used for circuits requiring heat resistance. ü Flame retardant ü Highly resistant against acids, lyes, petrol and diesel. ü Flexible conductors with Electron beam cross linked polyolefin general purpose insulation for smaller diameter and lesser weight. ü Extra flexibility. ü Heat resistant. ü Insulation : Electron beam cross linked polyolefin. ü Colour : As per customer order. ü Single core Wires & Cables 1.40 0.94 0.56 0.42 0.36 0.27 0.21 0.17 500 500 500 500 500 500 500 500 0 0 ü Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C. ü * Other length as per Customer order. * Max. Conductor Resistance 0 at 20 C Ω/km ü Conductor : Soft-annealed electrolytic copper E- Cu ETP1 according to ASTM B3 bare conductor construction according to SAE J 1127 Catalogue No 823 82361XX 82362XX 82363XX 82358XX 82334XX 82365XX 82366XX 82367XX 13 19 32 40 50 62 81 103 63 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 166 257 373 453 545 653 847 1052 124 160 218 255 281 325 381 808 8.60 10.5 12.0 13.0 14.5 16.0 18.5 20.0 1.06 1.16 1.16 1.16 1.16 1.16 1.39 1.39 1.52 1.65 1.65 1.65 1.65 1.65 1.98 1.98 Nom. Min. Siechem Wires & Cables Meet EU RoHS Directive AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949 Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 Red-White - A12 White-Green - A07 Orange-White - 73 White-Yellow - A08

RkJQdWJsaXNoZXIy NDgyMjA=