Automotive cable
Application Product Construction Technical Data Wires & Cables 2D View Siechem STX RoHS ü Temperature Range : 0 0 - 40 C to +125 C (3000 Hours) ü Standard : SAE J1127 : 2015 ü Test Voltage : 1 kV ü S : Starter (or) ground ü T : Thin wall ü X : Cross linked polyolefin Nominal Cross- Section No. of Strands Diameter of Single wire max. Conductor Construction Conductor Diameter Nom. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness 2 mm nos. mm mtrs kg/km mm Standard Length* Part Number Current Carrying Capacity mm mm mm Amps STX 13 19 32 40 50 62 81 103 133 133 133 259 1026 1254 1615 2052 0.36 0.46 0.57 0.46 0.26 0.26 0.26 0.26 4.83 6.09 7.67 8.49 9.47 10.47 11.89 13.40 1.09 1.12 1.12 1.12 1.12 1.12 1.12 1.12 Features ü Wire harness low-tension electric wire for automobiles. ü Used in motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Especially used for circuits requiring heat resistance. ü Flame retardant ü Highly resistant against acids, lyes, petrol and diesel. ü Flexible conductor with Electron beam cross linked polyolefin thin wall insulation for smaller diameter and lesser weight. ü Excellent flexibility. ü Heat resistant. ü Insulation : Electron beam cross linked polyolefin. ü Colour : As per customer order. ü Single core Wires & Cables Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 1.40 0.94 0.56 0.42 0.36 0.27 0.21 0.17 500 500 500 500 500 500 500 500 0 0 ü Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C. ü * Other length as per Customer order. * Max. Conductor Resistance 0 at 20 C Ω/km ü Conductor : Soft-annealed electrolytic Copper E- Cu ETP1 according to ASTM B3 bare conductor construction according to SAE J 1127 : 2015 Catalogue No 822 82261XX 82262XX 82263XX 82258XX 82234XX 82265XX 82266XX 82267XX 62 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 147 230 341 421 508 613 778 978 86 159 218 257 281 325 383 677 0.76 0.78 0.78 0.78 0.78 0.78 0.78 0.78 7.80 9.50 11.0 12.0 13.0 14.5 17.0 18.5 Nom Min Siechem Wires & Cables Meet EU RoHS Directive AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=