Automotive cable

Technical Data Wires & Cables Siechem TXL RoHS ü Temperature Range : 0 0 - 40 C to +125 C (3000 Hours) ü Standard : SAE J1128 :2015 ü Test Voltage : 1 kV ü T : Thin wall ü XL : Cross Linked Polyolefin Nominal Cross- Section No. of Strands Diameter of Single wire Max. Conductor Construction Conductor Diameter Nom. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness 2 mm nos. mm mtrs kg/km mm Standard Length* Part Number Current Carrying Capacity mm mm mm Amps TXL Application Product Construction Features 2D View ü Wire harness of low-tension electric circuits for automobiles. ü Used in motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Especially used for circuits requiring heat resistance. ü Flame retardant ü Highly resistant against acids, lyes, Petrol and diesel. ü Flexible conductors with Electron beam cross linked Polyolefin thin wall insulation for smaller diameter and lesser weight. ü Excellent flexibility. ü Heat resistant. Wires & Cables Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 * Max. Conductor Resistance 0 at 20 C Ω/km ü Conductor : Soft-annealed electrolytic copper bare conductor E- Cu ETP1 according to ATSM B3 construction according to SAE J 1128 ü Insulation : XLPO Electron beam cross linked polyolefin. ü Colour : As per customer order. ü Single core Catalogue No 819/C819 81902XX 81905XX 81906XX 81960XX 81910XX 81914XX 81917XX 81921XX 81925XX C81960XX C81925XX 53 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 4 5 7 10 15 22 31 46 80 10 80 9 13 16 21 27 36 49 66 88 21 88 1000 1000 1000 1000 1000 500 500 500 500 1000 500 0.40 0.40 0.40 0.40 0.40 0.40 0.46 0.50 0.55 0.40 0.55 0.28 0.28 0.28 0.28 0.28 0.28 0.32 0.35 0.39 0.28 0.39 0 0 ü Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C. ü * Other length as per Customer order. 0.21 0.26 0.31 0.26 0.29 0.36 0.45 0.57 0.71 0.23 0.45 0.63 0.78 0.93 1.21 1.45 1.80 2.25 2.85 3.55 1.21 3.55 7 7 7 16 19 19 19 19 19 19 49 1.5 1.7 1.9 2.2 2.4 2.7 3.3 4.0 4.9 2.2 4.9 84.4 52.0 35.7 24.7 15.4 9.30 5.90 3.70 2.40 24.7 2.40 0.22 0.35 0.5 0.8 1 2 3 5 8 0.8 8 Nom. Min Siechem Wires & Cables Meet EU RoHS Directive AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949

RkJQdWJsaXNoZXIy NDgyMjA=