Application Product Construction Technical Data Wires & Cables Siechem GPT RoHS ü Temperature Range : 0 0 - 40 C to +85 C (3000 Hours) ü Test voltage : 1kv ü Specification :SAE J 1128(2015) ü GP : General Purpose ü T : Thermoplastic insulation Size No. of Strands Diameter of Single wire max. Conductor Construction Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness AWG nos. mm mtrs kg/km mm Standard Length* Part Number mm mm GPT Features ü Type GPT wire may be whenever SAE J1128 Specifies general circuit wiring. ü Low tension primary cable for use at nominal Voltage of 60V DC (25V AC) ü For normal application with limited exposure to fluids and physical abuse ü Type GPT wire is available in solid colors and stripes with optional custom printing and / or numbering ü Insulation : PVC, Polyvinylchloride. ü Colour : As per customer order. ü Single core Wires & Cables Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 ü *Other length as per Customer order. 0 0 ü Current Carrying capacity given is for the maximum conductor operating temperature of 85 C and ambient air temperature of 40 C. * ü Conductor : Soft annealed electrolytic copper A880 A88082XX A88081XX A88080XX A88079XX A88078XX A88077XX A88076XX 50 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 20 18 16 14 12 10 8 7 16 19 19 19 19 19 0.31 0.26 0.29 0.36 0.45 0.57 0.71 0.58 0.58 0.58 0.58 0.66 0.79 0.94 0.41 0.41 0.41 0.41 0.46 0.55 0.66 2.4 2.5 2.9 3.2 3.8 4.7 6.0 10 15 16 24 37 59 90 500 500 500 500 500 500 500 Current Carrying Capacity Amps 13 17 23 30 41 54 71 Max Condctor Resistance at 20°C Ω/km 35.7 22.7 15.4 9.3 5.9 3.7 2.4 Conductor Diameter Nom 0.93 1.21 1.45 1.80 2.25 2.85 3.55 mm Catalogue No Nom. Min. Siechem Wires & Cables Meet EU RoHS Directive AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949

RkJQdWJsaXNoZXIy NDgyMjA=