Automotive catalogue

Application Product Construction Technical Data Wires & Cables Siechem GPT RoHS ü Temperature Range : 0 0 - 40 C to +85 C (3000 Hours) ü Test voltage : 1kv ü Specification :SAE J 1128 :2015 ü GP : General Purpose ü T : Thermoplastic insulation Size No. of Strands Diameter of Single wire max. Conductor Construction Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness 2 mm nos. mm mtrs kg/km mm Standard Length* Part Number mm Automotive Cables GPT Features ü Type GPT wire may be whenever SAE J1128 Specifies general circuit wiring. ü Low tension primary cable for use at nominal Voltage of 60V DC (25V AC) ü For normal application with limited exposure to fluids and physical abuse ü Type GPT wire is available in solid colors and stripes with optional custom printing and / or numbering ü Insulation : PVC, Polyvinylchloride. ü Colour : As per customer order. ü Single core Wires & Cables Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 ü *Other length as per Customer order. 0 0 ü Current Carrying capacity given is for the maximum conductor operating temperature of 85 C and ambient air temperature of 40 C. ** We have obtained various approvals, accreditations, and certifications — some of which may not be relevant to this catalog. * ü Conductor : Soft annealed electrolytic copper A880 A88006XX A88060XX A88010XX A88014XX A88017XX A88021XX A88025XX 44 www.siechem.com 0.5 0.8 1 2 3 5 8 7 16 19 19 19 19 19 0.31 0.26 0.29 0.36 0.45 0.57 0.71 0.58 0.58 0.58 0.58 0.66 0.79 0.94 2.4 2.5 2.9 3.2 3.8 4.7 6.0 10 15 16 24 37 59 90 500 500 500 500 500 500 500 Current Carrying Capacity Amps 13 17 22 29 39 52 69 Max Condctor Resistance at 20°C Ω/km 35.7 22.7 15.4 9.3 5.9 3.7 2.4 Conductor Diameter Nom 0.93 1.21 1.45 1.80 2.25 2.85 3.55 0.41 0.41 0.41 0.41 0.46 0.55 0.66 mm mm Catalogue No Nom. Min. All information given are in good faith. Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any other compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Progress throughResearch R TUV ** Certifications Approvals Accreditations ResearchDesign&StandardsOrganisation 2D View

RkJQdWJsaXNoZXIy NDgyMjA=