Automotive cable
Application Product Construction Technical Data Wires & Cables Features Wires & Cables Catalogue No C385 ü Conductor : Soft-annealed electrolytic copper E-Cu ETP1 according to JIS C 3102, bare conductor construction according to JASO D 624 ü Insulation : Specially formulated Cross Linked PE Mixture. ü Braiding : Annealed Tinned Copper ü Outer Sheath : Specially formulated Cross Linked 0 Elastomer 100 C ü Sheath Colour : Orange www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. ü Temperature Range : - 40°C to +120°C ü Standard : JASO D 624 ü Test Voltage : Insulation - 5 kV for 5 min. Sheath - 1 kV for 1 min. ü E : Use for EV ü E : Polyethylene Insulated ü X : Electron Beam Cross Linked ü S/BS : With Braided Shield ü f : Extra Flexible conductor ü Flame retardant ü Heat resistant ü Good flexibility ü Fire : Self extinguishing ü Soldering iron resistant ü Highly resistant against acids, lyes, petrol and diesel. ü Wire harness of low-tension electric circuits for automobiles. ü Used in motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Especially used for circuits requiring heat resistance. Siechem EEXS-f/EEXBS-f RoHS EEXS-f/EEXBS-f Nominal Cross- Section No. of Strands Diameter of Single wire Nom. Conductor Construction Conductor Diameter Approx. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness Nom. Sheath Thickness Nom. Braid Wire dia Nom. 2 mm nos. mm kg/km mm Part Number Current Carrying Capacity mm mm mm mm Amps * Max. Conductor Resistance 0 at 20 C Ω/km 36.7 14.7 9.50 6.06 3.59 2.33 1.90 0.494 0.377 Nom. mm 3.5 4.2 4.5 5.2 6.1 7.1 8.8 15.2 17.2 3.8 4.5 4.8 5.5 6.5 7.5 9.2 15.8 17.8 25 39 48 66 98 135 190 570 740 1.0 1.5 1.8 2.3 3.0 4.0 4.5 8.9 10.2 0.5f 1.25f 2f 3f 5f 8f 10f 40f 50f C38506XXYY C38512XXYY C38514XXYY C38517XXYY C38521XXYY C38525XXYY C38527XXYY C38558XXYY C38534XXYY 20 50 37 58 98 7/22 7/27 37/92 19/50 0.18 0.18 0.26 0.26 0.26 0.26 0.26 0.12 0.26 0.5 0.6 0.6 0.7 0.8 0.8 1.0 1.4 1.6 0.12 0.12 0.12 0.12 0.12 0.12 0.18 0.12 0.18 0.5 0.5 0.5 0.5 0.5 0.5 0.8 1.5 1.5 Note : XX*& YY* : Please add last two digits in the part number as per the colour code given hereunder replacing XX &YY while ordering, for Insulation and Sheath respectively. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 0 0 ü Current Carrying capacity given is for the maximum conductor operating temperature of 120 C and ambient air temperature of 40 C. 16 28 37 49 67 88 101 227 274 Siechem Wires & Cables Meet EU RoHS Directive 38 AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=