Automotive catalogue
All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Application Product Construction Technical Data Wires & Cables 2D View Siechem FLR2X T4 (A) Class D RoHS 0 0 ü Temperature Range: -40 C to +150 C (3000 Hours) ü Standard : ISO 6722 Class D (Thin wall) 2 ü Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm 2 5kV (r.m.s.) for cables ≥ 0.5 mm ü FL : Automotive Cable ü R : Reduced wall Thickness ü 2X : Cross Linked PE ü T4 : Temperature : -40°C to +150°C ü A : Symmetrical Conductor (Structure A) Features ü Low-tension electric wire for Automobiles. ü Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Conductor : Soft / annealed Plain Copper according to ASTM B3 ü Insulation : Electron Beam Cross Linked Polyethylene ü Colour : As per customer order ü Cable construction according to ISO 6722, Class D (Thin wall) ü Single core, Single layer insulation Wires & Cables ü Flame retardant ü Highly resistant against acids, lyes, Petrol and diesel ü Halogen free Nominal Cross- Section No. of Strands Diameter of Single wire Max. Conductor Construction Conductor Diameter Max. Cable Overall Diameter Weight Approx. Min. Max. Insulation Wall Thickness Nom. 2 mm nos. mm mm mtrs kg/km mm Standard Length* Part Number mm mm * Max. Conductor Resistance 0 at 20 C Ω/km 0.22 0.35 0.50 0.75 1 1.5 2 2.5 3 4 5 6 10 16 0.25 0.25 0.28 0.30 0.30 0.30 0.35 0.35 0.40 0.40 0.40 0.40 0.60 0.65 1.10 1.20 1.40 1.70 1.90 2.20 2.50 2.70 3.10 3.40 3.90 4.00 5.30 6.40 1.20 1.30 1.60 1.90 2.10 2.40 2.80 3.00 3.40 3.70 4.20 4.30 6.00 7.20 84.8 54.4 37.1 24.7 18.5 12.7 9.42 7.60 6.15 4.71 3.94 3.14 1.82 1.16 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 7 7 19 19 19 19 19 37 37 37 37 37 63 105 0.21 0.27 0.19 0.24 0.27 0.33 0.38 0.28 0.34 0.38 0.43 0.45 0.46 0.46 3 5 6 9 12 17 23 26 34 42 53 60 106 165 0.70 0.90 1.10 1.30 1.50 1.80 2.00 2.20 2.40 2.80 3.10 3.40 4.50 5.80 A76002XX A76005XX A76006XX A76008XX A76010XX A76013XX A76014XX A76016XX A76017XX A76019XX A76021XX A76023XX A76027XX A76028XX Current Carrying Capacity Amps 9 12 16 22 26 33 41 46 54 64 72 82 119 158 178 FLR2X T4 (A) Automotive Cables Progress throughResearch R TUV ** Certifications Approvals Accreditations ResearchDesign&StandardsOrganisation 2D View www.siechem.com Catalogue Number A760
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=