Automotive cable

Application Product Construction Technical Data Wires & Cables CABT 0.75 Sq.mm T3 Siechem CABT (T3) Features ü Low-tension electric wire for automobiles. ü Used in motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Flame retardant ü Highly resistant against acids, iyes, petrol and diesel. ü Heat resistance ü Halogen free Wires & Cables Catalogue No Y811 0 0 ü Temperature Range : -40 C to + 125 C ü Specification : MS 90034 & ISO 6722-1 ü System Voltage (Nom.) : ≤ 60V DC (or) 25V AC ü Max. Conductor Temperature Termination of Short Circuit : 280°C C - Temperature Class C A - Symmetrical B - Bare Copper T - Thin Wall ü Conductor : Soft-annealed electrolytic bare Copper according to ISO 6722-1 ü Cable construction according to ISO 6722-1 Class C (Thin wall) ü Insulation : Electron Beam Cross Linked Polyolefin 125°C ü Colour : As per customer order. ü Single core, single layer insulation Nominal Cross- Section No. of Strands Diameter of Single wire Max. Conductor Construction Conductor Diameter Max. Cable Overall Diameter Weight Approx. (Min/Max) Insulation Wall Thickness Nom. 2 mm nos. mm mtrs kg/km mm Standard Length* Part Number Current Carrying Capacity mm mm Amps * Max. Conductor Resistance 0 at 20 C Ω/km Y81105XX Y81106XX Y81108XX Y81110XX Y81113XX Y81114XX Y81116XX Y81117XX Y81119XX Y81121XX Y81123XX Y81125XX Y81127XX Y811A11XX Y81128XX Y81156XX Y81130XX 54.4 37.1 24.7 18.5 12.7 9.42 7.60 6.15 4.71 3.94 3.14 2.38 1.82 1.52 1.16 0.995 0.743 12 15 20 24 30 37 42 49 58 66 75 91 108 123 144 161 189 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 7 7 19 19 19 19 37 37 37 37 37 98 63 154 105 247 154 0.27 0.32 0.24 0.27 0.33 0.38 0.28 0.34 0.38 0.43 0.45 0.33 0.46 0.33 0.46 0.33 0.46 5 7 10 11 17 23 25 35 43 54 59 82 105 135 167 208 245 0.9 1.1 1.3 1.5 1.8 2.0 2.2 2.4 2.8 3.1 3.4 4.3 4.5 5.4 5.8 6.9 7.2 0.35 0.5 0.75 1 1.5 2 2.5 3 4 5 6 8 10 12 16 20 25 0.25 0.28 0.30 0.30 0.30 0.35 0.35 0.40 0.40 0.40 0.40 0.40 0.60 0.60 0.65 0.65 0.65 1.20/1.40 1.40/1.60 1.70/1.90 1.90/2.10 2.20/2.40 2.50/2.80 2.70/3.00 3.10/3.40 3.40/3.70 3.90/4.20 4.00/4.30 4.60/5.00 5.30/6.00 5.80/6.50 6.40/7.20 7.00/7.80 7.90/8.70 143 0 0 ü Current carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C. ü * Other length as per customer order. Siechem Wires & Cables Meet EU RoHS Directive AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949

RkJQdWJsaXNoZXIy NDgyMjA=