Automotive cable

Wires & Cables Siechem FLR6Y-B RoHS Wires & Cables Catalogue No A895 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 133 Application Product Construction Technical Data Features ü Temperature Range : - 40˚C to +210˚C (3000 Hours) 2 ü Test Voltage : 3kV (r.m.s.) for cables < 0.5 mm 2 5kV (r.m.s.) for cables ≥ 0.5 mm ü FL : Automotive Cable ü R : Reduced wall thickness ü 6Y : Fluorinated Ethylene Propylene ü B : Asymmetrical (Structure B) ü Standard : ISO 6722, Class F LV 112-1 ü Conductor : Soft-annealed electrolytic Copper E-Cu - ETP1 according to DIN 13602, bare conductor (Asymmetrical) ü Optional : Tinned ü Insulation : FEP (Fluorinated Ethylene Propylene), (Thin wall) ü Colour : As per customer order. ü Single core ü Suitable for inside engine compartment ü Low-tension electric wire for automobiles ü Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits ü Good mechanical and thermal properties ü Excellent chemical resistance ü Very good oil and fuel resistance ü High resistance to atmospheric conditions and ozone FLR6Y-B Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 o o ü Current Carrying capacity given is for the maximum conductor operating of 210 C and ambient air temperature of 40 C. ü * Other length as per Customer order. Nominal Cross- Section No. of Strands Diameter of Single wire max. Conductor Construction Conductor Diameter Max. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness Min. 2 mm nos. kg/km mm Part Number mm mm Max. Conductor Resistance 0 at 20 C Standard Length* Ω/km mm mtrs Current Carrying Capacity Amps 0.35 0.5 0.75 1.0 1.5 2.5 4 6 12 16 24 32 30 50 56 84 0.21 0.21 0.21 0.21 0.26 0.26 0.31 0.31 0.90 1.10 1.30 1.50 1.80 2.20 2.80 3.40 0.20 0.22 0.24 0.24 0.24 0.28 0.32 0.32 1.40 1.60 1.90 2.10 2.40 3.00 3.70 4.30 5 6 9 11 16 25 40 60 15 19 25 30 38 54 74 95 54.4 37.1 24.7 18.5 12.7 7.60 4.71 3.14 500 500 500 500 500 500 500 500 A89505XX A89506XX A89508XX A89510XX A89513XX A89516XX A89519XX A89523XX Siechem Wires & Cables Meet EU RoHS Directive AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949

RkJQdWJsaXNoZXIy NDgyMjA=