Automotive cable
C418 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Application Product Construction Technical Data Features Wires & Cables ü Temperature Range : - 40˚C to +200˚C (3000 Hours) 2 ü Test Voltage : 3kV (r.m.s.) for cables < 0.5 mm 2 5kV (r.m.s.) for cables ≥ 0.5 mm ü FL : Automotive Cable ü 2G : Silicone Rubber ü B : Asymmetrical (Structure B) ü Standard : ISO 6722, Class F ü Conductor : Soft-annealed electrolytic Copper E-Cu - ETP1 according to DIN 13602, bare conductor (Asymmetrical) ü Optional : Tinned ü Insulation : Silicone Rubber (Thick wall) ü Colour : As per customer order. ü Single core ü High flexibility at low temperatures ü Excellent ageing and high temperatures ü Fuel resistance Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 o o ü Current Carrying capacity given is for the maximum conductor operating of 200 C and ambient air temperature of 40 C. ü * Other length as per Customer order. Catalogue No FL2G- B Siechem B RoHS FL2G- ü High resistance requiring wiring systems ü Used in engine compartment, engine and gearbox wiring. ü Used in battery lead-wire for automobiles. Nominal Cross- Section No. of Strands Diameter of Single wire max. Conductor Construction Conductor Diameter Max. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness Min. 2 mm nos. kg/km mm Part Number mm mm Max. Conductor Resistance 0 at 20 C Standard Length* Ω/km mm mtrs Current Carrying Capacity Amps 0.5 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 C41806XX C41808XX C41810XX C41813XX C41813XX C41806XX C41806XX C41806XX C41806XX C41806XX C41806XX C41806XX C41806XX C41806XX 16 24 32 30 50 56 84 80 126 196 276 396 360 475 0.21 0.21 0.21 0.26 0.26 0.31 0.31 0.41 0.41 0.41 0.41 0.41 0.51 0.51 1.10 1.30 1.50 1.80 2.20 2.80 3.40 4.50 5.80 7.20 8.50 10.50 12.50 14.80 0.48 0.48 0.48 0.48 0.56 0.64 0.64 0.80 0.80 1.04 1.04 1.20 1.20 1.28 2.30 2.50 2.70 3.00 3.60 4.40 5.00 6.50 8.30 10.40 11.60 13.50 15.50 18.00 9 12 14 19 30 47 67 111 169 263 358 509 704 920 21 27 32 40 55 75 96 136 181 238 292 364 447 529 37.1 24.7 18.5 12.7 7.60 4.71 3.14 1.82 1.16 0.743 0.527 0.368 0.259 0.196 500 500 500 500 500 500 500 500 500 500 500 500 500 500 130 Siechem Wires & Cables Meet EU RoHS Directive AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=