Automotive catalogue
Application Product Construction Technical Data Wires & Cables 2D View Siechem FLRYW - A RoHS Nominal Cross- Section No. of Strands Diameter of Single wire max. Conductor Construction Conductor Diameter Nom. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness Nom. 2 mm nos. mm kg/km mm Part Number mm mm Features ü Low-tension electric wire for Automobiles. ü Suitable for application inside the engine compartment ü Cold resistant ü Highly resistant against acids, lyes, Petrol and diesel. ü Flexible conductors with PVC thin wall insulation ü Heat resistant Wires & Cables * Standard Length* A87505XX A87506XX A87508XX A87510XX A87513XX A87514XX mtrs ü Temperature Range : 0 0 - 50 C to +125 C (3000 Hours) 2 ü Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm 2 5kV (r.m.s.) for cables ≥ 0.5 mm ü FL: Automotive cable ü R: Reduced wall thickness ü YW: Hot pressure type ü Standard : DBL 6312 Ford ES-AU5T-1A348 ü Insulation : Soft PVC With properties according to ISO 6722, Class C Lead free ü Colour : As per customer order. ü Singl core E-Cu ETP1 according to DIN EN 13602, bare conductor ü Conductor : Soft-annealed electrolytic Copper 112 www.siechem.com All information given are in good faith. Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any other compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 7 19 19 19 19 19 0.26 0.19 0.23 0.26 0.32 0.38 0.8 1.0 1.2 1.35 1.7 2.0 1.3 1.6 1.9 2.1 2.4 2.8 5 6 9 11 16 22 0.35 0.5 0.75 1 1.5 2 0.20 0.22 0.24 0.24 0.24 0.28 500 500 500 500 500 500 54.4 37.1 24.7 18.5 12.7 9.42 Ω/km Max. Conductor Resistance 0 at 20 C Current Carrying Capacity Amps 11 15 19 23 30 37 Catalogue No A875 FLRYW-A Automotive Cables Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 0 0 ü Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C. ü * Other length as per Customer order. ** We have obtained various approvals, accreditations, and certifications — some of which may not be relevant to this catalog. Progress throughResearch R TUV ** Certifications Approvals Accreditations ResearchDesign&StandardsOrganisation 2D View
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=