Aero 55 Cables
Wires & Cables Wires & Cables Siechem AERO 55 600V Single Core Shielded Wires 30 28 26 24 22 20 18 16 14 12 10 8 7 7 19 19 19 19 19 19 19 37 37 133 0.10 0.13 0.10 0.13 0.16 0.20 0.25 0.29 0.36 0.32 0.40 0.29 55G40087XXYY 55G40086XXYY 55G40085XXYY 55G40084XXYY 55G40083XXYY 55G40082XXYY 55G40081XXYY 55G40080XXYY 55G40079XXYY 55G40078XXYY 55G40077XXYY 55G40076XXYY 5.06 5.80 6.85 8.19 10.27 13.40 17.86 21.73 30.36 42.41 62.65 110. 42 1.52 1.61 1.73 1.86 2.01 2.22 2.47 2.69 3.12 3.57 4.22 5.82 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No 55G400 www.siechem.com Application ü Temperature Rating i) Tin Plated Conductor ii) Silver or Nickel Plated Conductor ü Voltage Rating ü Scrape Abrasion ü Flexing Endurance ü Shrinkage ü Thermal Endurance ü Permitivity at 1KHz ü Dissipation Factor ü Conductor Annealed Tinned Copper Conductor (Optional Silver Coated Copper Conductor / Nickel Coated Copper Conductor) ü Insulation Radiation Cross-Linked Specially Formulated ETFE (Ethylene Tetrafluoroethylene) ü Shielding Annealed Tinned Copper. ü Outer sheath Radiation Cross-Linked Specially Formulated ETFE (Ethylene Tetrafluoroethylene) ü Single core ü Colour As Per Customer Order. : : : : : : : : : 0 0 -65 C to + 150 C 0 0 -65 C to + 200 C 600V, light weight >100 cycles >1000 cycles < 1 % 0 200 C, 10000h 2.7 0.001 Wire Size (AWG) No.of Strands (Nos.) Overall Diameter (Nom.) (mm) Diameter of Single Wire (Nom.) (mm) Part Number Cable Weight (Approx.) (kg/km) ü Hook up signal wire & cables used in aircraft, avionics, military electronics, satellites, helicopters, missiles, automobiles and appliances. : : : : : : Siechem AERO 55 600V Single Core Shielded Wires Note : XX* & YY* : Please add last two digits in the part number as per the colour code given hereunder replacing XX & YY while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Cross Section Area (Sq.mm) 0.051 0.08 0.13 0.20 0.33 0.52 0.82 1.31 2.08 3.31 5.26 8.37 Features Product Construction Technical Data ü Insulation does not shrink in hostile working environment . ü Better cut though resistance characteristics ü Single or dual wall constructions. ü Small size and light weight. ü No melting or dripping due to prolonging excess heat because of EBXL process. ü Resistance to soldering iron & over load. ü Excellent chemical resistance to many acids, carbon solvents, fuels, lubricants, missile fuels, oxidizers etc. 0 0 0 0 ü Temperature rating -65 C to + 200 C [-85 F to +392 F], stable installed performance in very hot, extremely cold and high vacuum conditions ü Outstanding electrical arc tracking resistance in wet and dry conditions. ü Very low toxic. ü Mechanical ruggedness. ü Good flexibility. ü Excellent scrape abrasion. ü RoHS Compliant. Standards ü SAE AS227759/32-35 and / 41 to / 46 ü NEMA-WC-27500(Cables) ü Def-Stan 61-12 Part 33 Issue 5 ü VDE 9426, 9427, 9428 ü British Standard 3G233 ü Boeing BMS 13-48 ü Airbus ABS 0820 to 0826 ü ASTM D150 AERO 55 15 Siechem Wires & Cables Meet EU RoHS Directive AS 9001 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=