AERO 44
Wires & Cables Wires & Cables Product Construction Technical Data ü Conductor Annealed Tinned Copper Conductor (Optional Silver Coated Copper Conductor / Nickel Coated Copper Conductor) ü Insulation Radiation Cross-Linked Specially Formulated Polyalkene Extruded ü Colour As Per Customer Order ü No. of cores 2 . Siechem AERO 44 600V Twisted Twin Core Cables Application Features ü Hook up signal wire & cables used in aircraft, avionics, military electronics, satellites, helicopters, missiles, automobiles and appliances. : : : : : 30 28 26 24 22 20 18 16 14 12 7 7 19 19 19 19 19 19 19 37 0.10 0.13 0.10 0.13 0.16 0.20 0.25 0.29 0.36 0.32 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No 44G10 www.siechem.com 2 2 2 2 2 2 2 2 2 2 1.39 1.54 1.75 2.05 2.40 2.81 3.32 3.67 4.54 5.50 2.38 3.13 4.47 6.69 9.82 14.73 22.32 28.42 44.35 69.00 Wire Size ( AWG) No.of Strands (Nos.) Overall Diameter (Nom.) (mm) Cable Weight (Max.) (kg/km) Diameter of Single Wire (Nom.) (mm) Part Number No.of Cores (Nos.) 44G108502 44G108402 44G108102 44G108202 44G108102 44G108002 44G107902 44G107802 44G107702 44G107602 ü Temperature Rating i) Tin Plated Conductor ii) Silver or Nickel Plated Conductor ü Voltage Rating(Thin wall) ü Tensile Strength ü Elongation of Insulation 0 ü Shrinkage,200 C ü Low Temperature Bend ü Flammability ü Resistance ü Smoke/Toxicity Index i) Smoke index ii) Toxicity index iii) Oxygen index iv) Temperature index : : : : : : : : : : : : : 0 0 -65 C to + 150 C 0 0 -65 C to + 200 C 600V, light weight 2 28 N/mm 230% < 1% 0 0 -65 C [-85 F] Pass Pass (fuels, oils, solvents) 6 per meter of wire 0.8 per meter of wire 30% Oxygen 0 0 > 300 C [572 F] AERO 55 44 ü Insulation does not shrink in hostile working environment . ü AERO 44 wires have 40% greater cut through resistance than some of the thickly insulated wires. ü Dual wall constructions. ü 600, 1000 and 2500 voltage rating. ü Small size and light weight. ü No melting or dripping due to prolonging excess heat, because of EBXL process. ü Resistance to soldering iron & over load. ü Excellent chemical resistance to many acids, carbon solvents, fuels, lubricants, missile fuels, oxidizers etc. 0 0 0 0 ü Temperature rating -65 C to + 200 C [-85 F to + 392 F] stable installed performance in very hot, extremely cold and available with low outgassing characteristics for use in an environment of high vacuum and high temperature. ü Outstanding electrical arc tracking resistance in wet and dry conditions. ü Very low toxic. ü Prevents cold flow of the insulations. ü Excellent scrape abrasion. ü Good flexibility. ü RoHS Compliant. Standards ü MIL-W-81044, MIL-C- 27500, MIL-C 7078, MIL -W- 16878, MIL-W-22759, MIL-STD-104, MIL-STD-681, MIL-STD-1916 ü VG 95218 Parts 20, 21, 22, 23 and 1000. ü MSV34401 ü BS G210, BS 4066 ü TDE 74/P/74 and TDE 75/R/6 ü S424 14751 ü Def - Stan. 61-12 Part 18 Issue 4/Part 26 Issue 3 ü NFC 32070 ü NES 714, NES 715 ü ASTM E 595 ü NEMA WC 27500 Cross Section Area (Sq.mm) 0.051 0.08 0.13 0.20 0.33 0.52 0.82 1.31 2.08 3.31 16 Siechem Wires & Cables Meet EU RoHS Directive AS 9001 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=