- Low-tension electric wire for Automobiles.
- Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.
- Especially used circuits requiring heat resistance
Part Number |
Conductor Construction | Insulation Wall Thickness Nom |
Cable | Max. Conductor Resistance at 200C |
Standard Length* |
||||
---|---|---|---|---|---|---|---|---|---|
Nominal Cross- Section |
No. of Strands |
Diameter of Single wire max. |
Conductor Diameter Nom. |
Overall Diameter Max |
Weight Approx. |
||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Ω/km | mtrs | |
86928XX* | 16 | 536 | 0.20 | 5.5 | 1.0 | 7.5 | 177 | 1.16 | 1000 |
86930XX | 25 | 826 | 0.20 | 9.7 | 1.3 | 9.7 | 275 | 0.74 | 1000 |
86932XX | 35 | 1184 | 0.20 | 11.2 | 1.3 | 11.2 | 369 | 0.527 | 1000 |
86934XX | 50 | 1144 | 0.23 | 13.0 | 1.5 | 13.0 | 525 | 0.368 | 500 |
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. | |||
Red – 01 | Yellow – 02 | Blue – 03 | Black – 04 |
Green – 05 | Yellow-Green – 06 | Grey – 07 | Brown – 08 |
White – 09 | Orange – 10 | Violet – 11 | Chocolate – 12 |
Tan – 13 | Charcoal – 14 | LT Blue – 15 | DK Grey – 16 |
LT Green – 17 | DK Green – 18 | DK Blue – 19 | Purple – 20 |
Pink – 21 |
Other length as per Customer order.
Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.