- Low-tension electric wire for Automobiles.
- Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.
Part Number |
Conductor Construction | Insulation Wall Thickness Nom. |
Cable | Max. Conductor Resistance at 200C |
Current Carrying Capacity |
Standard Length* |
|||||
---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Cross- Section |
No. of Strands |
Diameter of Single wire max. |
Conductor Diameter Nom. |
Overall Diameter | Weight Approx. |
||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | Ω/km | Amps | mtrs | |
80502XX* | 0.22 | 7 | 0.20 | 0.6 | 0.3 | 1.2 | 1.3 | 4 | 84.8 | 8 | 1000 |
80504XX | 0.3 | 7 | 0.26 | 0.8 | 0.3 | 1.4 | 1.5 | 5 | 50.2 | 9 | 1000 |
80506XX | 0.5 | 7 | 0.32 | 1.0 | 0.3 | 1.6 | 1.7 | 7 | 32.7 | 12 | 1000 |
80554XX | 0.85 | 19 | 0.24 | 1.2 | 0.3 | 1.8 | 1.9 | 10 | 21.7 | 15 | 1000 |
80512XX | 1.25 | 19 | 0.29 | 1.5 | 0.3 | 2.1 | 2.2 | 14 | 14.9 | 19 | 1000 |
80514XX | 2 | 19 | 0.37 | 1.9 | 0.4 | 2.7 | 2.8 | 23 | 9.00 | 26 | 500 |
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. | |||||||||
Red – 01 | Yellow – 02 | Blue – 03 | Black – 04 | Green – 05 | Yellow-Green – 06 | Grey – 07 | Brown – 08 | White – 09 | Orange – 10 |
Violet – 11 | Chocolate – 12 | Tan – 13 | Charcoal – 14 | LT Blue – 15 | DK Grey – 16 | LT Green – 17 | DK Green – 18 | DK Blue – 19 | Purple – 20 |
Pink – 21 |
Other length as per Customer order.
Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.