Siechem Single Core Stranded Class C (Thin Wall) 1000V AC EV 125 Cable

  • Especially used in supporting all line charging equipment.
  • AC & DC Charging (Domestic use & Public charging station).

  • Conductor : Annealed plain copper Conductor according to ISO 19642 (Stranded).
  • Insulation : Electron Beam crossed linked Polyolefin Class D (Thin wall )
  • Insulation Colour : Orange (or) as per customer request

  • Temperature Range : -40°C to 125°C (3000 Hours)
  • Max. Rated Voltage : i) 600V AC (or) 900V DC (0.35Sq.mm)
    ii) 1000V AC (or) 1500V DC (0.5Sq.mm and above)
    (ISO Condcutor size 0.35Sq.mm Shall not be used for 1000V AC (or) 1500V DC Cables)
  • Test Voltage : i) 3kV AC  for 5 mins ( 0.35Sq.mm)
    ii) 10kV AC for 5 mins ( ≥ 0.5Sq.mm)
  • Insulation Faults :  6 kV AC for 900V DC & 8kV AC for 1500V DC Cable
  • Specification : ISO 19642-5, ISO 6722 & Generally as per QC/T 1037-2016**

  • Abrasion Resistant.
  • Thermal Stress-resistant.
  • Halogen-free.
  • Flame Resistant.
  • Resistant to cold bend and low temperature shock.
  • High charging power upto 500KW.
  • Highly flexible and light weight therefore easy to handle at the charging station.
  • Active liquid cooling as protection against overheating.
  • Fast Charging.
  • Ozone resistant.
  • Soldering Iron Resistant
  • Resistant to liquid chemicals

Part
Number
Conductor Construction Insulation
Thickness
(Min.)
Cable Current
Carrying
Capacity
Max.
Conductor
Resistance
at 20 degC
Nominal
Cross-
Section
No. of
Strands
Strand
Diameter
(Max)
Overall
Diameter
Min/Max
Weight
Approx
mm2 nos. mm mm mm kg/km Amps  Ω/km
 A93805XX* 0.35 7 0.26 0.20 1.20/1.40 5 12 54.4
A93806XX 0.5 19 0.19 0.22 1.40/1.60 6 15 37.1
A93808XX 0.75 19 0.24 0.24 1.70/1.90 9 20 24.7
 A93810XX 1 19 0.27 0.24 1.90/2.10 11 24 18.5
A93812XX 1.25 19 0.30 0.24 2.10/2.30 14 27 14.9
A93813XX 1.5 19 0.33 0.24 2.20/2.40 16.5 30 12.7
 A93814XX 2 19 0.38 0.28 2.50/2.80 22.5 37 9.42
 A93816XX 2.5 37 0.30 0.28 2.70/3.00 26 42 7.60
 A93817XX 3 44 0.31 0.32 3.10/3.40 33 49 6.15
 A93819XX 4 56 0.31 0.32 3.40/3.70 41 58 4.71
 A93821XX 5 70 0.31 0.32 3.90/4.20 51 66 3.94
 A93823XX 6 84 0.31 0.32 4.00/4.30 60 75 3.14
 A93825XX 8 116 0.31 0.32 4.60/5.00 81 91 2.38
 A93827XX 10 144 0.31 0.48 5.30/6.00 104 108 1.82
 A938A11XX 12 174 0.31 0.48 5.80/6.50 124 123 1.52
 A93828XX 16 228 0.31 0.52 6.40/7.20 162 145 1.16
 A93856XX 20 276 0.31 0.52 7.00/7.80 195 164 0.955
 A93830XX 25 355 0.31 0.52 7.90/8.70 245 192 0.743
 A93857XX 30 408 0.31 0.64 8.70/9.60 285 209 0.647
 A93832XX 35 501 0.31 0.64 9.40/10.40 350 236 0.527
 A93858XX 40 558 0.31 0.71 10.00/11.10 390 252 0.473
 A93834XX 50 717 0.31 0.71 11.00/12.20 495 292 0.368
 A93835XX 60 838 0.31 0.80 12.00/13.30 575 322 0.315
 A93837XX 70 1019 0.31 0.80 13.00/14.40 695 360 0.259
 A93859XX 85 1197 0.31 0.90 14.40/15.80 820 397 0.219
 A93838XX 95 1347 0.31 0.90 15.30/16.70 920 427 0.196
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red – 01 Yellow – 02 Blue – 03 Black – 04
Green – 05 Yellow-Green – 06 Grey – 07 Brown – 08
White – 09 Orange – 10 Violet – 11 Chocolate – 12
Tan – 13 Charcoal – 14 LT Blue – 15  DK Grey – 16
LT Green – 17 DK Green – 18 DK Blue – 19 Purple – 20
Pink – 21

Other length as per Customer order.

Current Carrying capacity given is for the maximum conductor operating temperature of 150°C and ambient air temperature of 40°C.

**Conductor Construction as per ISO 19642-5. If customer insist construction to be as per ISO 6722 & Generally as per QC/T 1037-2016 or any specific construction, the same can also be supplied.