Menu

Products

More Category
Cables by Standard

Automotive Cables

Siechem Single Core Stranded Class C (Thick Wall) 1000V AC EV 125 Cable

  • Especially used in supporting all line charging equipment.
  • AC & DC Charging (Domestic use & Public charging station).

  • Conductor : Annealed plain copper Conductor according to ISO 19642 (Stranded).
  • Insulation : Electron Beam crossed linked Polyolefin Class D (Thick wall )
  • Insulation Colour : Orange (or) as per customer request

  • Temperature Range : -40°C to 125°C (3000 Hours)
  • Max. Rated Voltage : 1000V AC (or) 1500V DC (0.5Sq.mm and above)
  • Test Voltage : 10kV AC for 5 mins ( ≥ 0.5Sq.mm)
  • Insulation Faults : 8kV AC
  • Specification : ISO 19642-5, ISO 6722 & Generally as per QC/T 1037-2016**

  • Abrasion Resistant.
  • Thermal Stress-resistant.
  • Halogen-free.
  • Flame Resistant.
  • Resistant to cold bend and low temperature shock.
  • High charging power upto 500KW.
  • Highly flexible and light weight therefore easy to handle at the charging station.
  • Active liquid cooling as protection against overheating.
  • Fast Charging.
  • Ozone resistant.
  • Soldering Iron Resistant
  • Resistant to liquid chemicals

Part
Number
Conductor Construction Insulation
Thickness
(Min.)
Cable Current
Carrying
Capacity
Max.
Conductor
Resistance
at 20 degC
Nominal
Cross-
Section
No. of
Strands
Strand
Diameter
(Max)
Overall
Diameter
Min/Max
Weight
Approx
mm2 nos. mm mm mm kg/km Amps  Ω/km
A93806XX 0.5 19 0.19 0.48 2.00/2.30 9 17 37.1
A93808XX 0.75 19 0.24 0.48 2.20/2.50 12 21 24.7
 A93810XX 1 19 0.27 0.48 2.40/2.70 16 25 18.5
A93812XX 1.25 19 0.30 0.48 2.40/2.95 19 29 14.9
A93813XX 1.5 19 0.33 0.48 2.70/3.00 22 32 12.7
 A93814XX 2 19 0.38 0.48 3.00/3.30 27 38 9.42
 A93816XX 2.5 37 0.30 0.56 3.30/3.60 35 44 7.60
 A93817XX 3 44 0.31 0.56 3.80/4.10 38 51 6.15
 A93819XX 4 56 0.31 0.64 4.00/4.40 50 60 4.71
 A93821XX 5 70 0.31 0.64 4.50/4.90 58 68 3.94
 A93823XX 6 84 0.31 0.64 4.60/5.00 68 77 3.14
 A93825XX 8 116 0.31 0.64 5.00/5.90 90 94 2.38
 A93827XX 10 144 0.31 0.80 5.90/6.50 115 109 1.82
 A938A11XX 12 174 0.31 0.80 6.60/7.40 140 124 1.52
 A93828XX 16 228 0.31 0.80 7.70/8.30 175 147 1.16
 A93856XX 20 276 0.31 0.88 8.10/9.10 210 166 0.955
 A93830XX 25 355 0.31 1.04 9.40/10.40 275 193 0.743
 A93857XX 30 408 0.31 1.04 9.70/10.90 310 210 0.647
 A93832XX 35 501 0.31 1.04 9.60/11.60 370 236 0.527
 A93858XX 40 558 0.31 1.12 11.20/12.40 415 253 0.473
 A93834XX 50 717 0.31 1.20 11.50/13.50 530 291 0.368
 A93835XX 60 838 0.31 1.20 13.40/14.60 615 321 0.315
 A93837XX 70 1019 0.31 1.20 13.50/15350 740 359 0.259
 A93859XX 85 1197 0.31 1.28 14.80/16.80 870 396 0.219
 A93838XX 95 1347 0.31 1.28 16.00/18.00 970 424 0.196
 A93841XX 120 1726 0.31 1.28 17.70/19.70 1216 489 0.196
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red – 01 Yellow – 02 Blue – 03 Black – 04
Green – 05 Yellow-Green – 06 Grey – 07 Brown – 08
White – 09 Orange – 10 Violet – 11 Chocolate – 12
Tan – 13 Charcoal – 14 LT Blue – 15  DK Grey – 16
LT Green – 17 DK Green – 18 DK Blue – 19 Purple – 20
Pink – 21

Other length as per Customer order.

Current Carrying capacity given is for the maximum conductor operating temperature of 150°C and ambient air temperature of 40°C.

**Conductor Construction as per ISO 19642-5. If customer insist construction to be as per ISO 6722 & Generally as per QC/T 1037-2016 or any specific construction, the same can also be supplied.


Enquiry

  • flipbook

Call us now Email us now

Enquiry

Enquiry about this Product

CAPTCHA Image